Function library
Acceleration, deceleration, braking, stopping
7−26
L
EDB82MV752 EN 5.2
Special functions for the ramp function generator
Setting the ramp function generator to 0
The ramp function generator input of the main setpoint can be set to 0 under C0410/6:
The main setpoint decelerates to 0 Hz along the deceleration ramp (C0013) as long as the
function is active.
With setpoint summation or in controlled operation the drive can continue to run.
Stopping the ramp function generator
The ramp function generator of the main setpoint can be stopped under C0410/5
(NSET1−RFG1−STOP).
The ramp function generator output value remains the same as long as the function is active.