Questions and Answers

  • S
    Samantha ThomasSep 12, 2025
    How to troubleshoot Remote keypad fault on Lenze ESMD371L2YXA?
    • J
      Jonathan MezaSep 12, 2025
      If the Lenze Inverter shows 'Remote keypad fault', it means the remote keypad is disconnected. To resolve this, check the remote keypad connections.
  • M
    Meredith GonzalezAug 25, 2025
    Why Lenze DC Drives show earth fault?
    • M
      Melissa SimonAug 25, 2025
      An earth fault in Lenze DC Drives can occur if a motor phase is grounded, so you should check the motor and motor cable. It can also be due to excessive capacitive charging current of the motor cable, in this case use shorter motor cables with lower charging current.
  • R
    raymond85Aug 25, 2025
    What to do if Lenze DC Drives have controller overtemperature?
    • T
      Tracy BoydAug 26, 2025
      If the controller has an overtemperature, it means the controller is too hot inside. To resolve this, reduce the controller load and improve cooling.
  • A
    annette36Sep 23, 2025
    What causes automatic start to be inhibited in Lenze DC Drives?
    • C
      cgarzaSep 23, 2025
      If automatic start is inhibited in Lenze DC Drives, it is because c42 = 0. You should apply a LOW-HIGH signal change at terminal 28.
  • B
    brandonalvarezSep 12, 2025
    What does DC-injection brake active mean on Lenze Inverter?
    • M
      Matthew DickersonSep 12, 2025
      If the Lenze Inverter is showing 'DC-injection brake active', it means the DC-injection brake has been activated either via digital input or automatically. To deactivate it, ensure the digital input is LOW or wait for the holding time c06 to expire if it was activated automatically.
  • P
    Paul GarciaSep 18, 2025
    What to do if Lenze DC Drives show data on EPM not valid?
    • S
      Sean MooreSep 18, 2025
      If Lenze DC Drives indicate that the data on the EPM is not valid, it means the data is not valid for the controller. Use an EPM providing valid data or load the Lenze setting.
  • D
    Deborah ReedSep 5, 2025
    What to do for Controller overtemperature on Lenze ESMD371L2YXA Inverter?
    • V
      vjonesSep 5, 2025
      If the Lenze Inverter displays 'Controller overtemperature', it means the controller is too hot inside. To resolve this, reduce the controller load and improve cooling.
  • U
    uhodgeSep 6, 2025
    What does current limit reached mean on Lenze Inverter?
    • C
      Caitlin MyersSep 6, 2025
      If the Lenze Inverter shows 'Current limit reached', it indicates a controllable overload. This is managed automatically, as described in C22.
  • E
    Erik BurnettSep 18, 2025
    What to do if Lenze DC Drives show EPM error?
    • N
      Nathaniel PetersonSep 18, 2025
      If Lenze DC Drives display an EPM error, the EPM might be missing or defective. Power down the system and replace the EPM.
  • B
    Bradley RojasAug 30, 2025
    What causes motor overload on Lenze Inverter?
    • A
      Andrea BlairAug 30, 2025
      If the Lenze Inverter displays a motor overload (I2t overload), it means the motor is thermally overloaded. This can be due to: * Impermissible continuous current. * Frequent or excessively long acceleration processes. To resolve this: * Check the controller selection. * Check the setting of c20.

Lenze ESMD371L2YXA Specifications

General IconGeneral
Output Power0.37 kW
Frequency Range0-500 Hz
Protection ClassIP20
Cooling MethodConvection
Communication InterfaceRS-485