Questions and Answers

  • M
    meganjohnsonSep 12, 2025
    How to troubleshoot Remote keypad fault on Lenze Inverter?
    • H
      harrisjohnSep 12, 2025
      If the Lenze Inverter shows 'Remote keypad fault', it means the remote keypad is disconnected. To resolve this, check the remote keypad connections.
  • M
    Ms. Erika LawrenceAug 25, 2025
    Why Lenze DC Drives show earth fault?
    • A
      allenstevenAug 25, 2025
      An earth fault in Lenze DC Drives can occur if a motor phase is grounded, so you should check the motor and motor cable. It can also be due to excessive capacitive charging current of the motor cable, in this case use shorter motor cables with lower charging current.
  • B
    Bradley AndersenAug 25, 2025
    What to do if Lenze DC Drives have controller overtemperature?
    • J
      juliewilliamsAug 26, 2025
      If the controller has an overtemperature, it means the controller is too hot inside. To resolve this, reduce the controller load and improve cooling.
  • C
    Cameron PerrySep 23, 2025
    What causes automatic start to be inhibited in Lenze DC Drives?
    • J
      Jason BergerSep 23, 2025
      If automatic start is inhibited in Lenze DC Drives, it is because c42 = 0. You should apply a LOW-HIGH signal change at terminal 28.
  • T
    Terry BeckerSep 12, 2025
    What does DC-injection brake active mean on Lenze Inverter?
    • F
      Frank ButlerSep 12, 2025
      If the Lenze Inverter is showing 'DC-injection brake active', it means the DC-injection brake has been activated either via digital input or automatically. To deactivate it, ensure the digital input is LOW or wait for the holding time c06 to expire if it was activated automatically.
  • K
    knightkirkSep 18, 2025
    What to do if Lenze DC Drives show data on EPM not valid?
    • O
      ojacksonSep 18, 2025
      If Lenze DC Drives indicate that the data on the EPM is not valid, it means the data is not valid for the controller. Use an EPM providing valid data or load the Lenze setting.
  • L
    Lauren BurkeSep 5, 2025
    What to do for Controller overtemperature on Lenze ESMD223L4TXA Inverter?
    • H
      hgarciaSep 5, 2025
      If the Lenze Inverter displays 'Controller overtemperature', it means the controller is too hot inside. To resolve this, reduce the controller load and improve cooling.
  • M
    Melissa ClarkSep 6, 2025
    What does current limit reached mean on Lenze ESMD223L4TXA?
    • D
      Debra GrantSep 6, 2025
      If the Lenze Inverter shows 'Current limit reached', it indicates a controllable overload. This is managed automatically, as described in C22.
  • Q
    qnelsonSep 18, 2025
    What to do if Lenze DC Drives show EPM error?
    • L
      Laurie HoodSep 18, 2025
      If Lenze DC Drives display an EPM error, the EPM might be missing or defective. Power down the system and replace the EPM.
  • E
    Eileen BrooksAug 30, 2025
    What causes motor overload on Lenze ESMD223L4TXA Inverter?
    • W
      Whitney ThompsonAug 30, 2025
      If the Lenze Inverter displays a motor overload (I2t overload), it means the motor is thermally overloaded. This can be due to: * Impermissible continuous current. * Frequent or excessively long acceleration processes. To resolve this: * Check the controller selection. * Check the setting of c20.

Summary

Safety Information

General Safety Precautions

General safety warnings, risks of injury, and required qualifications for personnel.

Technical Data Overview

Product Ratings and Specifications

Detailed power, voltage, and current ratings for different models.

Installation Procedures

Electrical Installation and Wiring

EMC requirements, fuses, and cable cross-section recommendations.

Control Terminal Functions

Detailed description of each control terminal's function and settings.

Commissioning Guide

Troubleshooting and Fault Diagnosis

Error Codes and Solutions (cF-LF)

Detailed list of error codes, their causes, and corrective actions.

Error Codes and Solutions (OC1-SF)

Further error codes including short-circuit, earth fault, and overload.

Lenze ESMD223L4TXA Specifications

General IconGeneral
TypeInverter
Power Rating2.2 kW
Input Frequency50/60 Hz
Frequency0-500 Hz
Protection ClassIP20
Input Voltage380-480 V
Output Voltage0-480 V AC
Control Methodvector control
Communication InterfaceCANopen
Cooling MethodAir cooling