Questions and Answers

  • C
    Christopher DavidAug 23, 2025
    What to do if Lenze DC Drives show a short-circuit or overload?
    • L
      Laura NewmanAug 25, 2025
      If the Lenze DC Drives indicate a short-circuit or overload, the cause may be a short-circuit. You should find the reason for the short-circuit and check the motor cable. It can also be caused by excessive capacitive charging current of the motor cable, in this case use shorter motor cables with lower charging current. If the acceleration time is too short, increase the acceleration time and check the controller selection. Also, check wiring if the motor cable is defective and check the motor for internal faults. If there is frequent and long overload, check the controller selection.
  • A
    Andrew ScottSep 1, 2025
    How to fix communication error on Lenze Inverter?
    • M
      Melissa HillSep 1, 2025
      If the Lenze Inverter reports a communication error, it could be due to the serial timer timing out. In this case, check the serial link connections.
  • E
    Erika BautistaSep 1, 2025
    What causes undervoltage on DC bus in Lenze ESMD223L4TXA Inverter?
    • C
      carlsontimothySep 1, 2025
      If the Lenze Inverter shows 'Undervoltage on DC bus', the mains voltage might be too low. Check the mains voltage to ensure it is within the required range.
  • D
    Derek FloresSep 2, 2025
    How to resolve Lenze Inverter stop with inhibited outputs?
    • T
      Taylor TaylorSep 2, 2025
      If the Lenze Inverter stops and the outputs U, V, W are inhibited, it is because there is a LOW signal at terminal 28. To solve this, set terminal 28 to HIGH.
  • R
    Rachel CookSep 3, 2025
    How to troubleshoot Dynamic braking fault on Lenze ESMD223L4TXA Inverter?
    • L
      Laura WallSep 3, 2025
      If the Lenze Inverter is showing a Dynamic braking fault, it indicates that the dynamic braking resistors are overheating. To resolve this, increase the deceleration time.
  • J
    Joshua TaylorSep 4, 2025
    Why is Lenze Inverter output frequency 0 Hz?
    • T
      Timothy MartinSep 4, 2025
      If the Lenze Inverter's output frequency is 0 Hz and the outputs U, V, W are inhibited, it could be due to: * Setpoint = 0 Hz (C31 = 0): In this case, you need to perform a setpoint selection. * Quick stop activated through digital input or serial link: Deactivate the Quick stop.
  • T
    Thomas LeeSep 4, 2025
    Why are Lenze ESMD223L4TXA Inverter buttons not working?
    • T
      Tracy BarberSep 5, 2025
      If the Lenze Inverter indicates that the remote keypad is active, the buttons on the front of the controller are disabled. This is normal operation when the remote keypad is in use.
  • L
    Lauren BurkeSep 5, 2025
    What to do for Controller overtemperature on Lenze ESMD223L4TXA Inverter?
    • H
      hgarciaSep 5, 2025
      If the Lenze Inverter displays 'Controller overtemperature', it means the controller is too hot inside. To resolve this, reduce the controller load and improve cooling.
  • M
    Melissa ClarkSep 6, 2025
    What does current limit reached mean on Lenze ESMD223L4TXA?
    • D
      Debra GrantSep 6, 2025
      If the Lenze Inverter shows 'Current limit reached', it indicates a controllable overload. This is managed automatically, as described in C22.
  • B
    Brian GrahamSep 6, 2025
    How to fix No access to code on Lenze Inverter?
    • A
      adam93Sep 7, 2025
      If the Lenze Inverter displays 'No access to code', it means that changes can only be made when the controller is in OFF or 1nh. To proceed, set terminal 28 to LOW or inhibit by serial link.

Summary

Safety Information

General Safety Precautions

General safety warnings, risks of injury, and required qualifications for personnel.

Technical Data Overview

Product Ratings and Specifications

Detailed power, voltage, and current ratings for different models.

Installation Procedures

Electrical Installation and Wiring

EMC requirements, fuses, and cable cross-section recommendations.

Control Terminal Functions

Detailed description of each control terminal's function and settings.

Commissioning Guide

Troubleshooting and Fault Diagnosis

Error Codes and Solutions (cF-LF)

Detailed list of error codes, their causes, and corrective actions.

Error Codes and Solutions (OC1-SF)

Further error codes including short-circuit, earth fault, and overload.

Lenze ESMD223L4TXA Specifications

General IconGeneral
TypeInverter
Power Rating2.2 kW
Input Frequency50/60 Hz
Frequency0-500 Hz
Protection ClassIP20
Input Voltage380-480 V
Output Voltage0-480 V AC
Control Methodvector control
Communication InterfaceCANopen
Cooling MethodAir cooling