Questions and Answers

  • W
    William PowellSep 12, 2025
    How to troubleshoot Remote keypad fault on Lenze ESMD222L4TXA Inverter?
    • L
      Lisa JonesSep 12, 2025
      If the Lenze Inverter shows 'Remote keypad fault', it means the remote keypad is disconnected. To resolve this, check the remote keypad connections.
  • M
    Ms. Sandra HillAug 25, 2025
    Why Lenze DC Drives show earth fault?
    • V
      Victoria LongAug 25, 2025
      An earth fault in Lenze DC Drives can occur if a motor phase is grounded, so you should check the motor and motor cable. It can also be due to excessive capacitive charging current of the motor cable, in this case use shorter motor cables with lower charging current.
  • N
    nfordAug 25, 2025
    What to do if Lenze DC Drives have controller overtemperature?
    • J
      John GarciaAug 26, 2025
      If the controller has an overtemperature, it means the controller is too hot inside. To resolve this, reduce the controller load and improve cooling.
  • H
    Hector Scott Jr.Sep 23, 2025
    What causes automatic start to be inhibited in Lenze DC Drives?
    • J
      James HortonSep 23, 2025
      If automatic start is inhibited in Lenze DC Drives, it is because c42 = 0. You should apply a LOW-HIGH signal change at terminal 28.
  • P
    Pedro MorrisSep 12, 2025
    What does DC-injection brake active mean on Lenze ESMD222L4TXA Inverter?
    • J
      Joshua SimsSep 12, 2025
      If the Lenze Inverter is showing 'DC-injection brake active', it means the DC-injection brake has been activated either via digital input or automatically. To deactivate it, ensure the digital input is LOW or wait for the holding time c06 to expire if it was activated automatically.
  • J
    Jessica StanleySep 18, 2025
    What to do if Lenze DC Drives show data on EPM not valid?
    • C
      Christine HuntSep 18, 2025
      If Lenze DC Drives indicate that the data on the EPM is not valid, it means the data is not valid for the controller. Use an EPM providing valid data or load the Lenze setting.
  • A
    Amanda FarmerSep 5, 2025
    What to do for Controller overtemperature on Lenze ESMD222L4TXA?
    • T
      Tony PayneSep 5, 2025
      If the Lenze Inverter displays 'Controller overtemperature', it means the controller is too hot inside. To resolve this, reduce the controller load and improve cooling.
  • C
    Craig FryeSep 6, 2025
    What does current limit reached mean on Lenze ESMD222L4TXA?
    • D
      Diane BrewerSep 6, 2025
      If the Lenze Inverter shows 'Current limit reached', it indicates a controllable overload. This is managed automatically, as described in C22.
  • C
    Claudia GriffithSep 18, 2025
    What to do if Lenze DC Drives show EPM error?
    • R
      Robert KingSep 18, 2025
      If Lenze DC Drives display an EPM error, the EPM might be missing or defective. Power down the system and replace the EPM.
  • S
    Sara PeckAug 30, 2025
    What causes motor overload on Lenze Inverter?
    • E
      Edward RichardsAug 30, 2025
      If the Lenze Inverter displays a motor overload (I2t overload), it means the motor is thermally overloaded. This can be due to: * Impermissible continuous current. * Frequent or excessively long acceleration processes. To resolve this: * Check the controller selection. * Check the setting of c20.

Summary

Safety Information

Safety Information (continued)

DANGER! Capacitor Charge Warning

Warning about charged capacitors after power removal.

WARNING! Protective Device Check

Warning about opening protective devices indicating a fault.

Technical Data

Technical Data (continued)

Product Ratings and Specifications

Provides detailed power, voltage, current, and frequency ratings for different models.

Installation

Dimensions and Mounting Specifications

Provides dimensional drawings and mounting specs for various models.

Installation (continued)

WARNING! UL Fuse Requirements

UL requirement for fuse usage for specific voltage drives.

Control Terminals Configuration

Details the function and configuration of various control terminal connections.

EMC Installation Requirements

Specific guidance on meeting EMC standards, including shielding and filters.

STOP! Spinning Motor Braking

Advises on using DC injection braking for stopping a spinning motor.

Fuses and Cable Cross-sections

Recommendations for fuses, circuit breakers, and input power wiring.

Connection Diagram

Illustrates the electrical connections for the drive.

DANGER! Output Terminal Warning

Warning against connecting mains power to output terminals.

Commissioning

Parameter Setting Overview

Explains how to adjust operational parameters via the keypad.

Commissioning (continued)

Parameter Menu Details

Provides a detailed list and explanation of configurable parameters.

Digital Input E1 Configuration

Details configuration options for digital input E1.

WARNING! C02 Setting Overwrite

Warning about overwriting settings with parameter C02.

Troubleshooting & Fault Elimination

Error Code Troubleshooting

Lists error codes, their causes, and recommended remedies.

Trouble Shooting & Fault Elimination (continued)

Short-circuit, Earth Fault, and Overload (OC1, OC2, OC6)

Addresses short-circuit, earth fault, and motor overload (I2t) faults.

Lenze ESMD222L4TXA Specifications

General IconGeneral
Power Rating2.2 kW
Input Voltage380-480 V AC
Output Voltage0-480 V AC
Protection ClassIP20
Output Power2.2 kW
TypeInverter
Frequency50/60 Hz
Control MethodVector Control
Cooling MethodAir Cooled