  • B
    Bianca MaldonadoAug 23, 2025
    What to do if Lenze DC Drives show a short-circuit or overload?
    • J
      James LiuAug 25, 2025
      If the Lenze DC Drives indicate a short-circuit or overload, the cause may be a short-circuit. You should find the reason for the short-circuit and check the motor cable. It can also be caused by excessive capacitive charging current of the motor cable, in this case use shorter motor cables with lower charging current. If the acceleration time is too short, increase the acceleration time and check the controller selection. Also, check wiring if the motor cable is defective and check the motor for internal faults. If there is frequent and long overload, check the controller selection.
  • S
    stephanie25Sep 1, 2025
    How to fix communication error on Lenze Inverter?
    • C
      cookevanSep 1, 2025
      If the Lenze Inverter reports a communication error, it could be due to the serial timer timing out. In this case, check the serial link connections.
  • J
    jeffreymacdonaldSep 1, 2025
    What causes undervoltage on DC bus in Lenze ESMD222L4TXA Inverter?
    • C
      Craig KennedySep 2, 2025
      If the Lenze Inverter shows 'Undervoltage on DC bus', the mains voltage might be too low. Check the mains voltage to ensure it is within the required range.
  • C
    curtisjodiSep 2, 2025
    How to resolve Lenze Inverter stop with inhibited outputs?
    • J
      James BoydSep 2, 2025
      If the Lenze Inverter stops and the outputs U, V, W are inhibited, it is because there is a LOW signal at terminal 28. To solve this, set terminal 28 to HIGH.
  • R
    rporterSep 3, 2025
    How to troubleshoot Dynamic braking fault on Lenze ESMD222L4TXA Inverter?
    • Z
      zsmithSep 3, 2025
      If the Lenze Inverter is showing a Dynamic braking fault, it indicates that the dynamic braking resistors are overheating. To resolve this, increase the deceleration time.
  • R
    raymond30Sep 4, 2025
    Why is Lenze ESMD222L4TXA output frequency 0 Hz?
    • B
      Bryan TannerSep 4, 2025
      If the Lenze Inverter's output frequency is 0 Hz and the outputs U, V, W are inhibited, it could be due to: * Setpoint = 0 Hz (C31 = 0): In this case, you need to perform a setpoint selection. * Quick stop activated through digital input or serial link: Deactivate the Quick stop.
  • H
    heathercarrilloSep 4, 2025
    Why are Lenze ESMD222L4TXA Inverter buttons not working?
    • M
      Michael SnyderSep 4, 2025
      If the Lenze Inverter indicates that the remote keypad is active, the buttons on the front of the controller are disabled. This is normal operation when the remote keypad is in use.
  • A
    Amanda FarmerSep 5, 2025
    What to do for Controller overtemperature on Lenze ESMD222L4TXA?
    • T
      Tony PayneSep 5, 2025
      If the Lenze Inverter displays 'Controller overtemperature', it means the controller is too hot inside. To resolve this, reduce the controller load and improve cooling.
  • C
    Craig FryeSep 6, 2025
    What does current limit reached mean on Lenze ESMD222L4TXA?
    • D
      Diane BrewerSep 6, 2025
      If the Lenze Inverter shows 'Current limit reached', it indicates a controllable overload. This is managed automatically, as described in C22.
  • C
    Corey WilliamsSep 7, 2025
    How to fix No access to code on Lenze Inverter?
    • C
      Cory DuncanSep 7, 2025
      If the Lenze Inverter displays 'No access to code', it means that changes can only be made when the controller is in OFF or 1nh. To proceed, set terminal 28 to LOW or inhibit by serial link.

Summary

Safety Information

Safety Information (continued)

DANGER! Capacitor Charge Warning

Warning about charged capacitors after power removal.

WARNING! Protective Device Check

Warning about opening protective devices indicating a fault.

Technical Data

Technical Data (continued)

Product Ratings and Specifications

Provides detailed power, voltage, current, and frequency ratings for different models.

Installation

Dimensions and Mounting Specifications

Provides dimensional drawings and mounting specs for various models.

Installation (continued)

WARNING! UL Fuse Requirements

UL requirement for fuse usage for specific voltage drives.

Control Terminals Configuration

Details the function and configuration of various control terminal connections.

EMC Installation Requirements

Specific guidance on meeting EMC standards, including shielding and filters.

STOP! Spinning Motor Braking

Advises on using DC injection braking for stopping a spinning motor.

Fuses and Cable Cross-sections

Recommendations for fuses, circuit breakers, and input power wiring.

Connection Diagram

Illustrates the electrical connections for the drive.

DANGER! Output Terminal Warning

Warning against connecting mains power to output terminals.

Commissioning

Parameter Setting Overview

Explains how to adjust operational parameters via the keypad.

Commissioning (continued)

Parameter Menu Details

Provides a detailed list and explanation of configurable parameters.

Digital Input E1 Configuration

Details configuration options for digital input E1.

WARNING! C02 Setting Overwrite

Warning about overwriting settings with parameter C02.

Troubleshooting & Fault Elimination

Error Code Troubleshooting

Lists error codes, their causes, and recommended remedies.

Trouble Shooting & Fault Elimination (continued)

Short-circuit, Earth Fault, and Overload (OC1, OC2, OC6)

Addresses short-circuit, earth fault, and motor overload (I2t) faults.

Lenze ESMD222L4TXA Specifications

General IconGeneral
Power Rating2.2 kW
Input Voltage380-480 V AC
Output Voltage0-480 V AC
Protection ClassIP20
Output Power2.2 kW
TypeInverter
Frequency50/60 Hz
Control MethodVector Control
Cooling MethodAir Cooled