0.25 kW… 4.0 kW
V0004
SX03M
EN
Operating Instructions
smd
- frequency inverter
-en1
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Questions and Answers

  • M
    Mackenzie MclaughlinAug 15, 2025
    What to do if Lenze ESMD251X2SFA shows short-circuit or overload?
    • C
      Cassandra ThomasAug 16, 2025
      If the Lenze Inverter displays a short-circuit or overload error, this is likely due to a short-circuit condition. To resolve this, identify the cause of the short-circuit and inspect the motor cable.
  • J
    Judy CochranAug 18, 2025
    Why Lenze Inverter displays undervoltage on DC bus?
    • Y
      yrichardsonAug 19, 2025
      If you're seeing an undervoltage error on the DC bus of your Lenze Inverter, the mains voltage may be too low. Verify that the mains voltage is within the acceptable range.
  • D
    Daniel OwensAug 21, 2025
    How to fix motor overload (I2t overload) on Lenze ESMD251X2SFA?
    • L
      lopezmichaelAug 22, 2025
      If the Lenze Inverter indicates a motor overload (I2t overload), the motor is likely overheating due to an impermissible continuous current or frequent/lengthy acceleration. Address this by checking the controller selection and the setting of c20.
  • J
    Jennifer TorresAug 25, 2025
    What causes external error on Lenze Inverter?
    • L
      Lori ReedAug 26, 2025
      If your Lenze Inverter is showing an external error, it means the digital input “TRIP set” is active. To resolve this, you should remove the external error.
  • V
    Valerie RiveraAug 28, 2025
    How to deactivate DC-injection brake on Lenze ESMD251X2SFA Inverter?
    • W
      wfosterAug 28, 2025
      The DC-injection brake may be active on your Lenze Inverter because it was activated via digital input or automatically. To deactivate it, ensure the digital input is LOW, or wait for it to deactivate automatically after the holding time c06 has expired.
  • J
    Julie ClarkAug 30, 2025
    What to do if Lenze ESMD251X2SFA Inverter shows EPM error?
    • K
      Kevin WhiteAug 30, 2025
      If your Lenze Inverter displays an EPM error, the EPM is either missing or defective. Power down the Inverter and replace the EPM.
  • S
    Samantha JohnsonSep 2, 2025
    Why Lenze Inverter shows digital inputs not uniquely assigned?
    • J
      Julia MorenoSep 2, 2025
      If the Lenze Inverter indicates that digital inputs are not uniquely assigned, this means that E1...E3 are assigned with the same digital signals. Ensure that each digital signal is only used once.
  • N
    nmunozSep 5, 2025
    Why automatic start inhibited on Lenze Inverter?
    • M
      Melissa ZimmermanSep 5, 2025
      If automatic start is inhibited on your Lenze Inverter, it is because c42 = 0. Apply a LOW-HIGH signal change at terminal 28.
  • A
    ashley26Sep 8, 2025
    How to solve Lenze Inverter stop with inhibited outputs U, V, W?
    • R
      Raymond DanielsSep 8, 2025
      If the Lenze Inverter has stopped and outputs U, V, and W are inhibited, this is due to a LOW signal at terminal 28. Set terminal 28 to HIGH.
  • K
    Kevin DaySep 12, 2025
    Why Lenze ESMD251X2SFA output frequency is 0 Hz?
    • J
      Jason KellySep 12, 2025
      If the output frequency of your Lenze Inverter is 0 Hz and outputs U, V, W are inhibited, the setpoint is likely 0 Hz (C31 = 0). Perform setpoint selection.

Summary

Safety Information

General Safety Principles

General safety guidelines for Lenze controllers, including risks of injury and required personnel qualifications.

Operational Safety Precautions

Safety measures during operation, including post-disconnection precautions and protective covers.

Handling and Electrical Connections

Precautions for proper handling to avoid damage and guidelines for safe electrical connections according to regulations.

Installation

Mechanical Installation

Guidelines for physical mounting, dimensions, and environmental considerations for inverter installation.

Electrical Installation

Commissioning

Troubleshooting and Fault Elimination

Error Codes and Remedies

Detailed listing of error codes, their causes, and recommended remedies.

Lenze ESMD251X2SFA Specifications

General IconGeneral
Protection ClassIP20
Enclosure RatingIP20
Control TypeV/f control
Communication InterfacesRS485
Protection FeaturesOvercurrent, overvoltage, undervoltage, overtemperature, short circuit, earth fault
Cooling MethodAir-cooled
Ambient Temperature Range-10 to +50 °C
Storage Temperature Range-25 to +70 °C
Relative Humidity95% non-condensing
AltitudeUp to 1000 meters without derating