How to troubleshoot Remote keypad fault on Lenze Inverter?
- SShawn BassSep 12, 2025
If the Lenze Inverter shows 'Remote keypad fault', it means the remote keypad is disconnected. To resolve this, check the remote keypad connections.

How to troubleshoot Remote keypad fault on Lenze Inverter?
If the Lenze Inverter shows 'Remote keypad fault', it means the remote keypad is disconnected. To resolve this, check the remote keypad connections.
Why Lenze DC Drives show earth fault?
An earth fault in Lenze DC Drives can occur if a motor phase is grounded, so you should check the motor and motor cable. It can also be due to excessive capacitive charging current of the motor cable, in this case use shorter motor cables with lower charging current.
What to do if Lenze DC Drives have controller overtemperature?
If the controller has an overtemperature, it means the controller is too hot inside. To resolve this, reduce the controller load and improve cooling.
What causes automatic start to be inhibited in Lenze DC Drives?
If automatic start is inhibited in Lenze DC Drives, it is because c42 = 0. You should apply a LOW-HIGH signal change at terminal 28.
What does DC-injection brake active mean on Lenze ESMD152L4TXA Inverter?
If the Lenze Inverter is showing 'DC-injection brake active', it means the DC-injection brake has been activated either via digital input or automatically. To deactivate it, ensure the digital input is LOW or wait for the holding time c06 to expire if it was activated automatically.
What to do if Lenze DC Drives show data on EPM not valid?
If Lenze DC Drives indicate that the data on the EPM is not valid, it means the data is not valid for the controller. Use an EPM providing valid data or load the Lenze setting.
What to do for Controller overtemperature on Lenze Inverter?
If the Lenze Inverter displays 'Controller overtemperature', it means the controller is too hot inside. To resolve this, reduce the controller load and improve cooling.
What does current limit reached mean on Lenze ESMD152L4TXA Inverter?
If the Lenze Inverter shows 'Current limit reached', it indicates a controllable overload. This is managed automatically, as described in C22.
What to do if Lenze DC Drives show EPM error?
If Lenze DC Drives display an EPM error, the EPM might be missing or defective. Power down the system and replace the EPM.
What causes motor overload on Lenze Inverter?
If the Lenze Inverter displays a motor overload (I2t overload), it means the motor is thermally overloaded. This can be due to: * Impermissible continuous current. * Frequent or excessively long acceleration processes. To resolve this: * Check the controller selection. * Check the setting of c20.
Explains symbols and their meanings for warnings and notes in the manual.
Details conformity standards, approvals, and environmental conditions for the inverter.
Provides power, voltage, current, and frequency ratings for various inverter models.
Covers dimensions, mounting details, and torque specifications for inverter installation.
Provides detailed dimensions and mounting instructions for the inverter unit.
Details electrical connection requirements, including EMC and wiring.
Guidelines for installing the inverter to meet Electromagnetic Compatibility (EMC) standards.
Recommendations for appropriate fuses, circuit breakers, and cable sizes for power wiring.
Illustrates the wiring connections for power, control, and communication terminals.
Details the function and connections for each control terminal on the inverter.
Guide to setting operational parameters and configuring the inverter's functions.
Information about the EPM for storing and managing controller memory and settings.
Detailed list and explanation of available parameters for configuring the inverter.
Lists common operational statuses, their causes, and recommended remedies.
Details specific error codes, their causes, and corrective actions.