Instructions de mise en service
FR
SMD
Frequency Inverter
0.37 kW... 22 kW
Betriebsanleitun
DE
Instrucciones de funcionamiento
IT
Istruzioni di funzionamento
ES
Operating Instructions
EN
(13466184)

Questions and Answers

  • S
    Shawn SmithSep 12, 2025
    How to troubleshoot Remote keypad fault on Lenze Inverter?
    • S
      Shawn WeberSep 12, 2025
      If the Lenze Inverter shows 'Remote keypad fault', it means the remote keypad is disconnected. To resolve this, check the remote keypad connections.
  • G
    Gary LopezAug 25, 2025
    Why Lenze DC Drives show earth fault?
    • J
      jacqueline60Aug 25, 2025
      An earth fault in Lenze DC Drives can occur if a motor phase is grounded, so you should check the motor and motor cable. It can also be due to excessive capacitive charging current of the motor cable, in this case use shorter motor cables with lower charging current.
  • A
    anthonysmithAug 25, 2025
    What to do if Lenze DC Drives have controller overtemperature?
    • A
      Adam ArnoldAug 26, 2025
      If the controller has an overtemperature, it means the controller is too hot inside. To resolve this, reduce the controller load and improve cooling.
  • C
    Cheryl SanchezSep 23, 2025
    What causes automatic start to be inhibited in Lenze DC Drives?
    • C
      cthorntonSep 23, 2025
      If automatic start is inhibited in Lenze DC Drives, it is because c42 = 0. You should apply a LOW-HIGH signal change at terminal 28.
  • A
    Amber GilbertSep 12, 2025
    What does DC-injection brake active mean on Lenze ESMD751L4TXA Inverter?
    • J
      john60Sep 12, 2025
      If the Lenze Inverter is showing 'DC-injection brake active', it means the DC-injection brake has been activated either via digital input or automatically. To deactivate it, ensure the digital input is LOW or wait for the holding time c06 to expire if it was activated automatically.
  • R
    racheldunlapSep 18, 2025
    What to do if Lenze DC Drives show data on EPM not valid?
    • R
      Robert MccallSep 18, 2025
      If Lenze DC Drives indicate that the data on the EPM is not valid, it means the data is not valid for the controller. Use an EPM providing valid data or load the Lenze setting.
  • R
    Roger GarciaSep 5, 2025
    What to do for Controller overtemperature on Lenze ESMD751L4TXA Inverter?
    • J
      Jennifer GonzalezSep 5, 2025
      If the Lenze Inverter displays 'Controller overtemperature', it means the controller is too hot inside. To resolve this, reduce the controller load and improve cooling.
  • J
    Jordan JonesSep 6, 2025
    What does current limit reached mean on Lenze ESMD751L4TXA?
    • M
      Marie DominguezSep 6, 2025
      If the Lenze Inverter shows 'Current limit reached', it indicates a controllable overload. This is managed automatically, as described in C22.
  • M
    Mr. Philip Nichols MDSep 18, 2025
    What to do if Lenze DC Drives show EPM error?
    • K
      Kevin StricklandSep 18, 2025
      If Lenze DC Drives display an EPM error, the EPM might be missing or defective. Power down the system and replace the EPM.
  • B
    Brianna SawyerAug 30, 2025
    What causes motor overload on Lenze ESMD751L4TXA?
    • J
      joy57Aug 30, 2025
      If the Lenze Inverter displays a motor overload (I2t overload), it means the motor is thermally overloaded. This can be due to: * Impermissible continuous current. * Frequent or excessively long acceleration processes. To resolve this: * Check the controller selection. * Check the setting of c20.

Summary

Safety Information

General Safety Precautions

Covers general safety, risks from live parts, misuse, and the need for qualified personnel.

Operational Safety Guidelines

Emphasizes monitoring devices, protection against accidents, and proper closure of covers during operation.

Technical Data

Product Ratings and Specifications

Provides detailed ratings for power, voltage, current, and frequency for various models.

Installation

Control Terminal Connections

Detailed description and function of each terminal used for control connections.

Commissioning

Troubleshooting and Fault Elimination

Status Code Troubleshooting

Explains causes and remedies for various status codes like OFF, Inh, SEp, br, CL, LU, dEC, nEd.

Error Code Troubleshooting

Details causes and remedies for error codes such as CF, CFG, dF, EF, F2_FO, FC3, FC5, LE, JF.

Lenze ESMD751L4TXA Specifications

General IconGeneral
BrandLenze
ModelESMD751L4TXA
CategoryInverter
LanguageEnglish

Related product manuals