Questions and Answers

  • J
    John McclainAug 23, 2025
    What to do if Lenze DC Drives show a short-circuit or overload?
    • S
      Sarah WalkerAug 25, 2025
      If the Lenze DC Drives indicate a short-circuit or overload, the cause may be a short-circuit. You should find the reason for the short-circuit and check the motor cable. It can also be caused by excessive capacitive charging current of the motor cable, in this case use shorter motor cables with lower charging current. If the acceleration time is too short, increase the acceleration time and check the controller selection. Also, check wiring if the motor cable is defective and check the motor for internal faults. If there is frequent and long overload, check the controller selection.
  • X
    xhernandezSep 1, 2025
    How to fix communication error on Lenze ESMD751L4TXA Inverter?
    • M
      Maria ChavezSep 1, 2025
      If the Lenze Inverter reports a communication error, it could be due to the serial timer timing out. In this case, check the serial link connections.
  • M
    Mario JenkinsSep 1, 2025
    What causes undervoltage on DC bus in Lenze ESMD751L4TXA?
    • J
      Jessica RiveraSep 1, 2025
      If the Lenze Inverter shows 'Undervoltage on DC bus', the mains voltage might be too low. Check the mains voltage to ensure it is within the required range.
  • D
    Diane HarrisSep 2, 2025
    How to resolve Lenze ESMD751L4TXA Inverter stop with inhibited outputs?
    • D
      Donna BlairSep 2, 2025
      If the Lenze Inverter stops and the outputs U, V, W are inhibited, it is because there is a LOW signal at terminal 28. To solve this, set terminal 28 to HIGH.
  • M
    marthajacksonSep 3, 2025
    How to troubleshoot Dynamic braking fault on Lenze Inverter?
    • B
      Brenda GarzaSep 3, 2025
      If the Lenze Inverter is showing a Dynamic braking fault, it indicates that the dynamic braking resistors are overheating. To resolve this, increase the deceleration time.
  • E
    Eric TuckerSep 3, 2025
    Why is Lenze ESMD751L4TXA Inverter output frequency 0 Hz?
    • S
      Stephanie RobbinsSep 4, 2025
      If the Lenze Inverter's output frequency is 0 Hz and the outputs U, V, W are inhibited, it could be due to: * Setpoint = 0 Hz (C31 = 0): In this case, you need to perform a setpoint selection. * Quick stop activated through digital input or serial link: Deactivate the Quick stop.
  • J
    Jackie WilliamsSep 4, 2025
    Why are Lenze Inverter buttons not working?
    • J
      Jimmy KhanSep 4, 2025
      If the Lenze Inverter indicates that the remote keypad is active, the buttons on the front of the controller are disabled. This is normal operation when the remote keypad is in use.
  • R
    Roger GarciaSep 5, 2025
    What to do for Controller overtemperature on Lenze ESMD751L4TXA Inverter?
    • J
      Jennifer GonzalezSep 5, 2025
      If the Lenze Inverter displays 'Controller overtemperature', it means the controller is too hot inside. To resolve this, reduce the controller load and improve cooling.
  • J
    Jordan JonesSep 6, 2025
    What does current limit reached mean on Lenze ESMD751L4TXA?
    • M
      Marie DominguezSep 6, 2025
      If the Lenze Inverter shows 'Current limit reached', it indicates a controllable overload. This is managed automatically, as described in C22.
  • J
    John ThompsonSep 7, 2025
    How to fix No access to code on Lenze Inverter?
    • L
      Linda HoweSep 7, 2025
      If the Lenze Inverter displays 'No access to code', it means that changes can only be made when the controller is in OFF or 1nh. To proceed, set terminal 28 to LOW or inhibit by serial link.

Summary

Safety Information

General Safety Precautions

Covers general safety, risks from live parts, misuse, and the need for qualified personnel.

Operational Safety Guidelines

Emphasizes monitoring devices, protection against accidents, and proper closure of covers during operation.

Technical Data

Product Ratings and Specifications

Provides detailed ratings for power, voltage, current, and frequency for various models.

Installation

Control Terminal Connections

Detailed description and function of each terminal used for control connections.

Commissioning

Troubleshooting and Fault Elimination

Status Code Troubleshooting

Explains causes and remedies for various status codes like OFF, Inh, SEp, br, CL, LU, dEC, nEd.

Error Code Troubleshooting

Details causes and remedies for error codes such as CF, CFG, dF, EF, F2_FO, FC3, FC5, LE, JF.