How to troubleshoot Remote keypad fault on Lenze ESMD402L4TXA?
- OooliverSep 12, 2025
If the Lenze Inverter shows 'Remote keypad fault', it means the remote keypad is disconnected. To resolve this, check the remote keypad connections.

How to troubleshoot Remote keypad fault on Lenze ESMD402L4TXA?
If the Lenze Inverter shows 'Remote keypad fault', it means the remote keypad is disconnected. To resolve this, check the remote keypad connections.
Why Lenze DC Drives show earth fault?
An earth fault in Lenze DC Drives can occur if a motor phase is grounded, so you should check the motor and motor cable. It can also be due to excessive capacitive charging current of the motor cable, in this case use shorter motor cables with lower charging current.
What to do if Lenze DC Drives have controller overtemperature?
If the controller has an overtemperature, it means the controller is too hot inside. To resolve this, reduce the controller load and improve cooling.
What causes automatic start to be inhibited in Lenze DC Drives?
If automatic start is inhibited in Lenze DC Drives, it is because c42 = 0. You should apply a LOW-HIGH signal change at terminal 28.
What does DC-injection brake active mean on Lenze ESMD402L4TXA Inverter?
If the Lenze Inverter is showing 'DC-injection brake active', it means the DC-injection brake has been activated either via digital input or automatically. To deactivate it, ensure the digital input is LOW or wait for the holding time c06 to expire if it was activated automatically.
What to do if Lenze DC Drives show data on EPM not valid?
If Lenze DC Drives indicate that the data on the EPM is not valid, it means the data is not valid for the controller. Use an EPM providing valid data or load the Lenze setting.
What to do for Controller overtemperature on Lenze Inverter?
If the Lenze Inverter displays 'Controller overtemperature', it means the controller is too hot inside. To resolve this, reduce the controller load and improve cooling.
What does current limit reached mean on Lenze Inverter?
If the Lenze Inverter shows 'Current limit reached', it indicates a controllable overload. This is managed automatically, as described in C22.
What to do if Lenze DC Drives show EPM error?
If Lenze DC Drives display an EPM error, the EPM might be missing or defective. Power down the system and replace the EPM.
What causes motor overload on Lenze ESMD402L4TXA Inverter?
If the Lenze Inverter displays a motor overload (I2t overload), it means the motor is thermally overloaded. This can be due to: * Impermissible continuous current. * Frequent or excessively long acceleration processes. To resolve this: * Check the controller selection. * Check the setting of c20.
Covers general safety, installation, and electrical connection guidelines for the inverter.
Details directives for intended application, operation, and explosion proof considerations.
Explains safety pictographs and provides notes for UL approved systems.
Lists conformity standards, approvals, and environmental operating conditions.
Provides key power, voltage, current, and frequency ratings of the inverter.
Details the physical mounting requirements and dimensions for the inverter.
Covers electrical connection, EMC requirements, fuses, and wiring diagrams.
Explains how to set parameters and use the Electronic Programming Module.
Outlines the structure and navigation of the inverter's parameter menu.
Details settings for digital inputs, relay outputs, and network configuration.
Covers parameters for frequency, acceleration, deceleration, and boost.
Explains analog input setup, fixed setpoints, and feedback signal configuration.
Summarizes operational statuses, common causes, and recommended remedies.
Lists specific error codes and provides troubleshooting steps for each.
Analyzes specific fault types such as short-circuit, earth fault, and overload.