Instructions de mise en service
FR
SMD
Frequency Inverter
0.37 kW... 22 kW
Betriebsanleitun
DE
Instrucciones de funcionamiento
IT
Istruzioni di funzionamento
ES
Operating Instructions
EN
(13466184)

Questions and Answers

  • S
    Scott Wise MDAug 23, 2025
    What to do if Lenze DC Drives show a short-circuit or overload?
    • A
      Austin VegaAug 25, 2025
      If the Lenze DC Drives indicate a short-circuit or overload, the cause may be a short-circuit. You should find the reason for the short-circuit and check the motor cable. It can also be caused by excessive capacitive charging current of the motor cable, in this case use shorter motor cables with lower charging current. If the acceleration time is too short, increase the acceleration time and check the controller selection. Also, check wiring if the motor cable is defective and check the motor for internal faults. If there is frequent and long overload, check the controller selection.
  • S
    Sandra TuckerSep 1, 2025
    How to fix communication error on Lenze ESMD402L4TXA Inverter?
    • S
      Samuel PriceSep 1, 2025
      If the Lenze Inverter reports a communication error, it could be due to the serial timer timing out. In this case, check the serial link connections.
  • K
    Kevin JohnsonSep 1, 2025
    What causes undervoltage on DC bus in Lenze ESMD402L4TXA?
    • L
      Leroy RiversSep 1, 2025
      If the Lenze Inverter shows 'Undervoltage on DC bus', the mains voltage might be too low. Check the mains voltage to ensure it is within the required range.
  • J
    Justin WallSep 2, 2025
    How to resolve Lenze ESMD402L4TXA Inverter stop with inhibited outputs?
    • N
      Nichole ColeSep 2, 2025
      If the Lenze Inverter stops and the outputs U, V, W are inhibited, it is because there is a LOW signal at terminal 28. To solve this, set terminal 28 to HIGH.
  • J
    Jordan Scott DDSSep 3, 2025
    How to troubleshoot Dynamic braking fault on Lenze ESMD402L4TXA Inverter?
    • B
      Benjamin JuarezSep 3, 2025
      If the Lenze Inverter is showing a Dynamic braking fault, it indicates that the dynamic braking resistors are overheating. To resolve this, increase the deceleration time.
  • J
    Jessica MooreSep 4, 2025
    Why is Lenze Inverter output frequency 0 Hz?
    • R
      Richard SilvaSep 4, 2025
      If the Lenze Inverter's output frequency is 0 Hz and the outputs U, V, W are inhibited, it could be due to: * Setpoint = 0 Hz (C31 = 0): In this case, you need to perform a setpoint selection. * Quick stop activated through digital input or serial link: Deactivate the Quick stop.
  • J
    Jeffrey PattersonSep 4, 2025
    Why are Lenze ESMD402L4TXA Inverter buttons not working?
    • A
      Angela KempSep 4, 2025
      If the Lenze Inverter indicates that the remote keypad is active, the buttons on the front of the controller are disabled. This is normal operation when the remote keypad is in use.
  • J
    Julie MccarthySep 5, 2025
    What to do for Controller overtemperature on Lenze Inverter?
    • C
      Craig RamirezSep 5, 2025
      If the Lenze Inverter displays 'Controller overtemperature', it means the controller is too hot inside. To resolve this, reduce the controller load and improve cooling.
  • M
    Melvin BlairSep 6, 2025
    What does current limit reached mean on Lenze Inverter?
    • M
      Ms. Kathy MasonSep 6, 2025
      If the Lenze Inverter shows 'Current limit reached', it indicates a controllable overload. This is managed automatically, as described in C22.
  • J
    Jill WeberSep 7, 2025
    How to fix No access to code on Lenze ESMD402L4TXA Inverter?
    • A
      Amy PachecoSep 7, 2025
      If the Lenze Inverter displays 'No access to code', it means that changes can only be made when the controller is in OFF or 1nh. To proceed, set terminal 28 to LOW or inhibit by serial link.

Summary

Safety Information

General Safety Precautions

Covers general safety, installation, and electrical connection guidelines for the inverter.

Application and Operation Directives

Details directives for intended application, operation, and explosion proof considerations.

Pictographs and UL Compliance Notes

Explains safety pictographs and provides notes for UL approved systems.

Technical Data

Standards and Application Conditions

Lists conformity standards, approvals, and environmental operating conditions.

Device Ratings and Specifications

Provides key power, voltage, current, and frequency ratings of the inverter.

Installation

Mechanical Installation and Mounting

Details the physical mounting requirements and dimensions for the inverter.

Electrical Installation and Wiring

Covers electrical connection, EMC requirements, fuses, and wiring diagrams.

Commissioning

Parameter Setting and EPM Usage

Explains how to set parameters and use the Electronic Programming Module.

Parameter Menu Navigation

Outlines the structure and navigation of the inverter's parameter menu.

Input;Output and Digital Configuration

Details settings for digital inputs, relay outputs, and network configuration.

Frequency, Timing, and Boost Settings

Covers parameters for frequency, acceleration, deceleration, and boost.

Analog Input and Setpoint Configuration

Explains analog input setup, fixed setpoints, and feedback signal configuration.

Troubleshooting and Fault Elimination

Status, Cause, and Remedy Overview

Summarizes operational statuses, common causes, and recommended remedies.

Error Code Reference Guide

Lists specific error codes and provides troubleshooting steps for each.

Detailed Fault Condition Analysis

Analyzes specific fault types such as short-circuit, earth fault, and overload.

Lenze ESMD402L4TXA Specifications