Questions and Answers

  • A
    Andrew ScottSep 1, 2025
    How to fix communication error on Lenze Inverter?
    • M
      Melissa HillSep 1, 2025
      If the Lenze Inverter reports a communication error, it could be due to the serial timer timing out. In this case, check the serial link connections.
  • M
    meganjohnsonSep 12, 2025
    How to troubleshoot Remote keypad fault on Lenze Inverter?
    • H
      harrisjohnSep 12, 2025
      If the Lenze Inverter shows 'Remote keypad fault', it means the remote keypad is disconnected. To resolve this, check the remote keypad connections.
  • E
    Eileen BrooksAug 30, 2025
    What causes motor overload on Lenze ESMD223L4TXA Inverter?
    • W
      Whitney ThompsonAug 30, 2025
      If the Lenze Inverter displays a motor overload (I2t overload), it means the motor is thermally overloaded. This can be due to: * Impermissible continuous current. * Frequent or excessively long acceleration processes. To resolve this: * Check the controller selection. * Check the setting of c20.
  • S
    Sharon SilvaSep 13, 2025
    What does it mean when Lenze DC Drives reach the current limit?
    • S
      Scott SmithSep 14, 2025
      Reaching the current limit in Lenze DC Drives indicates a controllable overload, which is managed automatically.
  • A
    Amy YoungSep 13, 2025
    What causes overvoltage on DC bus in Lenze DC Drives and how to fix it?
    • R
      Rachel WhiteSep 13, 2025
      Overvoltage on the DC bus in Lenze DC Drives can be caused by several factors. It may be due to mains voltage being too high, so you should check the mains voltage. Another cause can be an excessively short deceleration time or the motor operating in generator mode; in this case, increase the deceleration time or use a dynamic braking option. Finally, earth leakage on the motor side can also cause this issue, so check the motor and motor cable, separating the motor from the controller.
  • K
    knightkirkSep 18, 2025
    What to do if Lenze DC Drives show data on EPM not valid?
    • O
      ojacksonSep 18, 2025
      If Lenze DC Drives indicate that the data on the EPM is not valid, it means the data is not valid for the controller. Use an EPM providing valid data or load the Lenze setting.
  • C
    Cameron PerrySep 23, 2025
    What causes automatic start to be inhibited in Lenze DC Drives?
    • J
      Jason BergerSep 23, 2025
      If automatic start is inhibited in Lenze DC Drives, it is because c42 = 0. You should apply a LOW-HIGH signal change at terminal 28.
  • J
    Joshua GibsonAug 27, 2025
    How to resolve dynamic braking fault in Lenze DC Drives?
    • F
      frank29Aug 27, 2025
      A dynamic braking fault in Lenze DC Drives typically means that the dynamic braking resistors are overheating. To resolve this, increase the deceleration time.
  • A
    Angel HillAug 26, 2025
    What to do if Lenze DC Drives show undervoltage on DC bus?
    • T
      tyler42Aug 26, 2025
      If Lenze DC Drives show undervoltage on the DC bus, it could be because the mains voltage is too low. Check the mains voltage.
  • B
    Bradley AndersenAug 25, 2025
    What to do if Lenze DC Drives have controller overtemperature?
    • J
      juliewilliamsAug 26, 2025
      If the controller has an overtemperature, it means the controller is too hot inside. To resolve this, reduce the controller load and improve cooling.

Summary

Safety Information

General Safety Precautions

General safety warnings, risks of injury, and required qualifications for personnel.

Technical Data Overview

Product Ratings and Specifications

Detailed power, voltage, and current ratings for different models.

Installation Procedures

Electrical Installation and Wiring

EMC requirements, fuses, and cable cross-section recommendations.

Control Terminal Functions

Detailed description of each control terminal's function and settings.

Commissioning Guide

Troubleshooting and Fault Diagnosis

Error Codes and Solutions (cF-LF)

Detailed list of error codes, their causes, and corrective actions.

Error Codes and Solutions (OC1-SF)

Further error codes including short-circuit, earth fault, and overload.

Lenze ESMD223L4TXA Specifications

General IconGeneral
TypeInverter
Power Rating2.2 kW
Input Frequency50/60 Hz
Frequency0-500 Hz
Protection ClassIP20
Input Voltage380-480 V
Output Voltage0-480 V AC
Control Methodvector control
Communication InterfaceCANopen
Cooling MethodAir cooling