EDB8210UE-V020
400753
Operating Instructions
Global Drive
Frequency Inverters
8210 HVAC Series
HVACandPumpDrives
Power Range 0.75 - 11 kW
Typ
Id.-NR
Fert.-Nr
Serien-Nr.
Eingang1
Eingang2
Lenze
Postfach 101352 ,31763 HAMELN
Typ
Id.-NR
Fert.-Nr
Serien-Nr.
Eingang1
Eingang2
Lenze
Postfach 101352 ,31763 HAMELN
Show/Hide Bookmarks

Table of Contents

Questions and Answers

  • N
    Nicholas CampbellSep 8, 2025
    Why is the current consumption of my Lenze EVF8217-EV020 DC Drives motor too high?
    • J
      Julie WaltersSep 8, 2025
      High current consumption in the motor can be attributed to a few settings. The setting of C016 might be too high, or the setting of C015 might be too low. Additionally, C088 and C091 might not be adapted to the motor data.
  • G
    Glenda ThompsonSep 9, 2025
    What causes grounded motor phase in Lenze EVF8217-EV020?
    • V
      Vanessa BurgessSep 9, 2025
      A grounded motor phase can be caused by a grounded motor phase. Check the motor and cable. Also, excessive capacitive charging current of the motor cable can lead to a grounded motor phase; use a motor cable which is shorter or of lower capacitance.
  • M
    Michael WilliamsSep 12, 2025
    Why is my Lenze EVF8217-EV020 DC Drives motor not rotating smoothly?
    • N
      Nathan MillerSep 12, 2025
      If the motor isn't rotating smoothly, it could be due to a defective motor cable. The maximum current C022 and C023 might also be set too low. Another possibility is that the motor is underexcited or overexcited; check the parameter setting.
  • L
    Lauren RodriguezSep 13, 2025
    What to do if mains voltage is too high in Lenze DC Drives?
    • A
      Angela HouseSep 13, 2025
      If the mains voltage is too high, check the voltage supply. It could also be due to feedback operation during braking. Increase deceleration times. For operation with brake choppers, check the selection and connection of the brake resistor and increase the deceleration times. Another cause may be Earth leakage on the motor side, check motor cable and motor for earth fault (disconnect motor from inverter).
  • T
    Tiffany FletcherSep 15, 2025
    What causes faulty parameter transfer via the operating module in Lenze EVF8217-EV020 DC Drives?
    • N
      Nicole NewtonSep 15, 2025
      If PAR1 and PAR2 are defective, it can cause a faulty parameter transfer. It is absolutely necessary to repeat the data transfer or load the factory setting before enabling the controller.
  • R
    Rebecca BarnesSep 18, 2025
    What causes faulty auto-TRIP reset in Lenze EVF8217-EV020?
    • P
      Phillip TranSep 18, 2025
      Faulty auto-TRIP reset is caused by more than 8 fault messages in 10 minutes. The solution depends on the fault message.

Summary

1 Preface and general information

1.2 Scope of delivery

Details the items included in the product package upon delivery.

1.3 Legal regulations

Outlines legal requirements and directives applicable to the product.

2 Safety information

2.1 General safety information

Provides essential safety and application notes for safe operation.

2.3 Residual hazards

Details potential hazards that may remain even after safety measures are taken.

3 Technical data

3.1 General data;application conditions

Specifies general operating and environmental conditions for the controller.

3.2 Rated data (Operation with 120% overload)

Provides electrical and performance data for 120% overload operation.

3.3 Rated data (Operation with 150% overload)

Provides electrical and performance data for 150% overload operation.

3.4 Fuses and cable cross-sections

Specifies fuses and cable cross-sections for different overload conditions.

3.5 Analog plug-in module

Describes the functionality and capabilities of the analog plug-in module.

3.6 Dimensions

Provides physical dimensions of the controller and plug-in module.

4 Installation

4.1 Mechanical installation

Key considerations and precautions for mechanical installation.

4.2 Electrical Installation

Crucial notes and precautions for electrical installation.

4.3 Installation of a CE-typical drive system

Guidelines for installing a CE-compliant drive system for EMC.

5 Commissioning

5.1 Before you switch on

Checks and preparations required before initial power-up.

5.2 Short set-up (Factory setting)

Step-by-step procedure for initial power-on and basic setup.

5.3 Adapt machine data

Adjusting drive parameters like speed range, acceleration, and current limits.

5.4 Optimisation of the operating characteristic of the drive

Fine-tuning drive performance by selecting control modes and parameters.

5.5 Operation with the PID controller

Utilizing the internal PID controller for process control applications.

5.6 Application examples

Practical examples of drive configuration for HVAC and pump systems.

6 During operation

7 Configuration

7.1 Basics

Introduction to controller configuration and available functions.

7.2 Code table

Explains how to read and interpret the parameter code table.

8 Troubleshooting and fault elimination

8.1 Troubleshooting

Identifying and diagnosing operational issues and malfunctions.

8.2 Fault analysis using the history buffer

How to analyze faults using the controller's internal history buffer.

8.3 Fault indications

Lists common fault codes, their causes, and recommended remedies.

8.4 Reset of fault indications

Procedures for resetting fault indications and acknowledgments.

9 Accessories (Overview)

9.1 Accessories for all types

Lists general accessories compatible with all controller types.

9.3 Type-specific accessories

Lists accessories specific to different controller model series.

Lenze EVF8217-EV020 Specifications

General IconGeneral
BrandLenze
ModelEVF8217-EV020
CategoryDC Drives
LanguageEnglish