Troubleshooting and fault elimination
Display of operating data, diagnostics
Display of operating data
4
30
EDKVF93−03 EN 2.0
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0064 Utilization 0 {1 %} 150 Device utilisation I×t
l Read only
l Device utilisation during the last
180 s of operating time
l C0064 > 100 % releases warning
OC5
l C0064 > 140 % limits the output
current of the controller to 67 % of
the maximum current in C0022
C0150 Status word
Bit00 Bit08 Status code
Read only
Decimal status word for networking
via automation interface (AIF)
l Binary interpretation indicates the
bit states
Bit01 IMP Bit09 Status code
Bit02
Bit10 Status code
Bit03
Bit11 Status code
Bit04
Bit12 Warning
Bit05
Bit13 Message
Bit06
n = 0 Bit14
Bit07
CINH Bit15