Preface and general information
1-7
 SHB9300CRV EN 2.0
Considered basic standards for the test of the noise emission:
Basic standard Test Limit value
EN 55022 7/92 Radio interference housing and mains
Frequency range 0.15 - 1000 MHz
Class B
for use in residential areas and
commercial premises
EN 55011 7/92
(used in addition to the requirements of
IEC 22G)
Radio interference housing and mains
Frequency range 0.15 - 1000 MHz
The emission of noise in industrial premises is not limited in
IEC 22G.
Class A
for use in
industrial premises
IEC 801-2 /91 Electrostatic discharge
on housing and heatsink
Severity 3
6 kV for contact,
8 kVclearance
IEC 1000-4-3 Electromagnetic fields
Frequency range 26 - 1000 MHz
Severity 3
10 V/m
ENV 50140 /93 High-frequency field
Frequency range 80 - 1000 MHz,
80% amplitude-modulated
Severity 3
10 V/m
Fixed frequency
900 MHz with 200 Hz, 100 % modulated
10 V/m
IEC 801-4 /88 Fast transients,
burst on power terminals
Severity 3
2kV/5kHz
Burst on bus and control cables Severity 4
2kV/5kHz
IEC 801-5 Surge test
mains cables
Installation class 3
Hameln, 01 January,1997
(i.V.Funk) (i.V.Lackhove)
Product Manager Project Manager