Configuration
7-289
SHB9300CRV EN 2.0
7.9 Code table
How to read the code table:
Column Abbreviation Meaning
Code C0039
1
2
¡
14
15
Code C0039
Subcode 1 of code C0039
Subcode 2 of code C0039
¡
Subcode 14 of code C0039
Subcode 15 of code C0039
[C0005] Parameter value of the code can only be modified when controller is inhibited
LCD Keypad LCD
l
DIS: ... Only display
l
CFG: ... Configured value is indicated on the LCD of the keypad
l
All other are parameter values
Lenze Factory setting of the code
* The column ”Important” contains further information
Selection 1{1%}99Minimum value {smallest step/unit} maximum value
IMPORTANT - Additional, important explanation of the code
&
7-289 Reference on page with further information on the code.
Code LCD
Possible settings
Important
Lenze Selection
ABS
[C0661] CFG: IN 1000 FIXED 0 %
@
Selection list 1 Analog input absolute value generator
C0662 DIS: C0661 -199.99 {0.01 %} 199.99 Display of C0661
ADD
[C0610]
1
2
3
CFG: IN1
CFG: IN2
CFG:IN3
1000 FIXED0%
@
Selection list 1 Adds inputs IN1, IN2 and IN3
C0611 DIS: C0610/1 ... 3 -199.99 {0.01 %} 199.99
AIF
C0136
3
DIS: CTRLWORD Control word in AIF-IN
C0151 DIS: FDO (DW) Output signals configured with C0116 Hexadecimal signal assignment of the free
digital outputs.
l
Binary interpretation indicates the bit
states
[C0850]
1
2
3
CFG: OUT.W1
CFG: OUT.W2
CFG: OUT.W3
1000 FIXED 0 %
@
Selection list 1 Configuration process output words for au-
tomation interface AIF (X1)
[C0851] CFG: OUT.D1 1000 FIXED 0INC
@
Selection list 3 Configuration 32-bit phase information
C0852 Type OUT.W2 0 0 Analog signal
1 Digital 0-15
2 Low phase
3 High phase
Configuration process output word 2 for au-
tomation interface AIF (X1)
C0853 Type OUT.W3 0 0 Analog signal
1 Digital 16-31
2 High phase
Configuration pocess output word 3 for au-
tomation interface AIF (X1)
C0854 Type OUT.W1 0 0 Analog signal
3 D2: Low phase
Configuration process output word 1 for au-
tomation interface AIF (X1)
C0855 DIS: IN (0-15)
DIS: IN (16-31)
Bit 00 {1} Bit 15 Process input words hexadecimal for auto-
mation interface X1
C0856
1
2
3
DIS: IN.W1
DIS: IN.W2
DIS: IN.W3
-199.99 {0.01%} 199.99 Process input words decimal
Display: 100% = 16384