Troubleshooting and fault elimination
8-7
SHB9300CRV EN 2.0
Display RemedyCauseFaultFault
No.
2)
OC1 11 Short-circuit
Short-circuit. Find out cause of short-circuit; check cable.
O
C
1
1
1
S
h
o
r
t
-
c
i
r
c
u
i
t
Excessive capacitive charging current of the motor
cable.
Use motor cable which is shorter or of lower
capacitance.
OC2 12 Earth fault
One of the motor phases has earth contact.
l
Check motor
l
Check supply cables
Excessive capacitive charging current of the motor
cable.
Use motor cable which is shorter or of lower
capacitance.
OC5 15 Ixtoverload Frequent and too long acceleration with overcurrent
Continuous overload with I
motor
>1.05xI
rx.
Check drive dimensioning.
OH 50 heatsink temperature is
higher than the value set
i
n
t
h
e
c
o
n
t
r
o
l
l
e
r
Ambient temperature T
amb
>40
Cor50
C.
l
Allow controller to cool and ensure better ventilation.
l
Check ambient temperature in the control cabinet.
i
n
t
h
e
c
o
n
t
r
o
l
l
e
r
heatsink very dirty. Clean heatsink
Incorrect mounting position. Change mounting position.
OH3
1)
53 heatsink temperature is
higher than the value set
i
n
t
h
e
c
o
n
t
r
o
l
l
e
r
Motor too hot because of excessive current or frequent
and too long acceleration
Check drive dimensioning.
h
i
g
h
e
r
t
h
a
n
t
h
e
v
a
l
u
e
s
e
t
in the controller
No PTC connected. Connect PTC or switch-off monitoring (C0583=3).
OH4 54 heatsink temperature is
higher than the value set
u
n
d
e
r
C
0
1
2
2
.
Ambient temperature T
amb
>40
Cor50
C.
l
Allow controller to cool and ensure better ventilation.
l
Check ambient temperature in the control cabinet.
u
n
d
e
r
C
0
1
2
2
.
heatsink very dirty. Clean heatsink
Incorrect mounting position. Change mounting position.
Value set under C0122 was too low. Enter higher value.
OH7
1)
57 Motor temperature is
higher than the value set
u
n
d
e
r
C
0
1
2
1
.
Motor too hot because of excessive current or frequent
and too long acceleration
Check drive dimensioning.
h
i
g
h
e
r
t
h
a
n
t
h
e
v
a
l
u
e
s
e
t
under C0121.
No PTC connected. Connect PTC or switch-off monitoring (C0584=3).
Value set under C0121 was too low. Enter higher value.
OH8 58 PTC at terminals T1, T2
indicates motor overheat.
Motor too hot because of excessive current or frequent
and too long acceleration
Check drive dimensioning.
i
n
d
i
c
a
t
e
s
m
o
t
o
r
o
v
e
r
h
e
a
t
.
Terminals T1, T2 are not assigned. Connect PTC or thermostat or switch off monitoring
(C0585=3).
OU 20 Overvoltage Excessive brake energy (DC bus voltage higher than set
under C0173).
Use brake module or energy recovery module.
P01 151 Limit switch negative Negative limit switch was reached.
l
Control drive in positive direction.
l
Check terminal connection X5/E2.
P02 152 Positive limit switch Positive limit switch was reached.
l
Control drive in negative direction.
l
Check terminal connection X5/E1.
P03 153 Contouring error
Phase difference between set and actual position is
larger than the contouring error limit set under C0255.
l
Extend contouring error limit under C0255
l
Switch off the monitoring if necessary (C0589 = 3).
Drive cannot follow the digital frequency (I
max
limit). Check drive dimensioning.
P04 154 Negative position limit Negative position limit (C1224) was not reached. Find out why the value was not reached (e.g. incorrect
position targets, set function position value) and adjust
the negative position limit (C1224) if necessary.
P05 155 Positive position limit Positive position limit (C1223) was exceeded. Find out why the value was exceeded (e.g. ”incorrect”
position targets, set function position value) and adjust
the positive position limit (C1223) if necessary.
P06 156 No reference The homing point is unknown. For absolute positioning
no homing was performed before the first positioning.
Perform one of the following functions and restart:
l
Manual homing.
l
Start homing in the program.
l
Set reference.
Show/Hide Bookmarks

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze EVS9323-EK and is the answer not in the manual?

Lenze EVS9323-EK Specifications

General IconGeneral
BrandLenze
ModelEVS9323-EK
CategoryDC Drives
LanguageEnglish

Related product manuals