Function library
Function blocks
3.5.59 Switching points (SP)
3−252
l
EDSVS9332P−EXT DE 2.0
SP2
SP2
C1651/1
C1651/2
C1651/3
C1651/4
C1651/5
C1651/6
C1651/7
C1651/8
C1651/9
C1652/1
SP2-STAT1
SP2-STAT2
SP2-STAT3
SP2-STAT4
SP2-STAT5
SP2-STAT6
SP2-STAT7
SP2-STAT8
C1651/10
C1651/11
C1651/12
C1651/13
C1651/14
C1651/15
C1651/16
C1658
C1657
C1655
VTPOS
SP2-L-IN
IN1-1
IN1-2
IN2-1
IN2-2
IN3-1
IN3-2
IN4-1
IN4-2
IN5-1
IN5-2
IN6-1
IN6-2
IN7-1
IN7-2
IN8-1
IN8-2
C1654/1
C1659
C1650/1
SP2-RESET
C1653/1
Fig. 3−200 Function block SP2
Signal
Source Note
Name Type DIS DIS format CFG List
SP2−L−IN ph C1654/1 dec [inc] C1652/1 3 65536 inc = 1 revolution
SP2−RESET d C1653/1 bin C1650/1 2
SP2−STAT1 d
SP2−STAT2 d
SP2−STAT3 d
SP2−STAT4 d
SP2−STAT5 d
SP2−STAT6 d
SP2−STAT7 d
SP2−STAT8 d
Function
l Switching points (start/end, center/range)
l Switching hysteresis
l Switching dead time
l Switching filter time constant

Table of Contents