Standard sengs
Parameter Value Comment
Name Delivery Seng range
Parameter set name --- [text] File name of the parameter set without le
extension *.lsm
Output speed 1 depending on the order [-2600/i ... -500/i] rpm
[0] rpm
[500/i ... 2600/i] rpm
CCW rotaon: < 0 rpm
STOP: 0 rpm
CW rotaon: > 0 rpm
Lenze Smart Motor with gearbox: The rao i is
taken into account when calculang the output
speed.
Output speed 2
Output speed 3
Output speed 4
Output speed 5
Acceleraon me [0.0 ... 20.0] s
Acceleraon me t
1
of the ramp generator from
0 rpm to n
max
[2600/i] rpm
Deceleraon me Deceleraon me t
2
of the ramp generator from
n
max
[2600/i] rpm to 0 rpm
Energy-saving funcon [O] Opmized for:
•
High dynamic performance
•
Maximum starng torque and torque
•
High speed accuracy
[On] Reduced energy absorpon in paral load
operaonal range.
Approx. 50 % of the maximum starng torque is
available.
Diagnoscs
Parameter Value Comment
Designaon Delivery Seng range
Peak load of the drive --- [0 … 250] % Last peak value of the medium thermal load
(maximum value in the last mains switching cycle)
From rmware version 03.00.00.00
Peak load of the brake resistor --- [0 … 250] % Last peak value of the thermal ulisaon of the
brake resistor (maximum value in the last mains
switching cycle)
From rmware version 03.00.00.00
Meters
Parameter Value Comment
Designaon Delivery Seng range
Elapsed-hour meter --- [0 ... 596523] h Total me of "Motor rotang"
Operang-hour meter --- [0 ... 596523] h Total me of "mains ON"
Logbook
Parameter Value Comment
Designaon Delivery Seng range
Error message 1 (last) --- [Text] Meaning: See fault eliminaon table
Error message 2 --- [Text]
Error message 3 --- [Text]
Error message 4 (earliest) --- [Text]
Commissioning
43