Mechanical installation
Dismounting the components
Loosening the central thread
4
24
Lenze ¯ MA 12.0022 ¯ 2.0
4.2.3 Removing the retaining clip
3
4
5
Fig. 3 Loosening and removing the securing screw
3 Securing screw 5 Securing cam
4 Retaining clip
4.2.4 Loosening the central thread
Stop!
Before unscrewing the central thread, ensure that the weight of the
motor and gearbox is still securely retained and carried after the two
parts have been separated.
1. Fit retaining clip with the securing screw on the opposite side of the securing cam,
Fig. 4.
2. Tighten the securing screw until the securing cams of the gearbox housing and
motor are flush with the retaining clip, Fig. 5.
Tightening torques of the screws ( 28).
3
4
5
Fig. 4 Mounting on the opposite side (start of screw tightening process)
3 Securing screw 5 Securing cam
4 Retaining clip