Standard sengs
Parameter Value Comment
Designaon
Delivery Seng range
Parameter set name [Text] File name of the parameter set without le
extension *.lsm
Output speed 1 depending on the
order
-2600 ... -500 rpm
0 rpm
500 ... 2600 rpm
CCW rotaon: < 0 rpm
STOP: 0 rpm
CW rotaon: > 0 rpm
Lenze Smart motor with gearbox: The rao i
is taken into account in the calculaon of the
output speed.
Output speed 2
Output speed 3
Output speed 4
Output speed 5
Acceleraon me [0.0 ... 20.0] s
n
max
t
Acceleraon me t
1
of the ramp generator
from 0 rpm to n
max
[2600/i] rpm
Deceleraon me Deceleraon me t
2
of the ramp generator
from n
max
[2600/i] rpm to 0 rpm
Energy-saving funcon [O] Opmised for:
High dynamic performance
Maximum starng torque and torque
High speed accuracy
[On] Reduced energy absorpon in paral load
operaonal range.
Approx. 50 % of the maximum starng tor-
que are available.
Diagnoscs
Parameter Value Comment
Designaon Delivery Seng range
Peak load of the drive --- [0 … 250] % Last peak value of the medium thermal load
(maximum value in the last mains switching
cycle)
From rmware version 03.00.00.00
Peak load of the brake resis-
tor
--- [0 … 250] % Last peak value of the medium thermal load
(maximum value in the last mains switching
cycle)
From rmware version 03.00.00.00
Meters
Parameter Value Comment
Designaon Delivery Seng range
Elapsed-hour meter --- [0 ... 596523] h Total me of "Motor rotang"
Operang‐hour meter --- [0 ... 596523] h Total me of "mains ON"
Logbook
Parameter Value Comment
Designaon
Delivery Seng range
Error message 1 (last) --- [Text] Meaning: See fault eliminaon table
Error message 2 --- [Text]
Error message 3 --- [Text]
Error message 4 (earliest) --- [Text]