Mechanical installation
Preparation
Mounting the fixed cover
4
35
Lenze ¯ MA 12.0013 ¯ 3.0
4.3.10 Mounting the fixed cover
Note!
This cover can be ordered optionally and will then be loosely enclosed
with the shipment, or it is already mounted to the gearbox.
Gearbox size: S130/G50BS113 ... S950/G50BS195
With these sizes, the protective cap is clipped on.
X
X
Clip the protection cover into the bores, 6 x flange side, 4 x motor side.
Gearbox size: S2100/G50BS221 ... S19000/G50BS319
With these sizes, the cover is screwed together with the housing.
Gearbox size: S2100/G50BS221 ... S4500/G50BS245
With these sizes, additional reducing bushs are screwed into the gearbox housing
thread.
2
x
x
1
3
1 Protection cover 3 Reducing bush
2 Cheese head screw
1. Screw reducing bushes (3) into the flange so that they are flush using a
screwdriver.
2. Fasten the protective cap (1) over the reducing bushes (3) on the flange using
cheese head screws (2).