Safety instructions
General safety instructions for drive components
2
11
Lenze BA 12.0023 9.0
If you do not install the motor immediately, ensure proper storage conditions.
Up to one year:
Shafts and uncoated surfaces are delivered in a protected against rust status.
Aftertreatment is required where the corrosion protection has been damaged.
Remove the plug for motors with condensation drain holes (special version).
More than one year, up to two years:
Apply a long-term corrosion preventive (e.g. Anticorit BW 366 from the Fuchs
company) to the shafts and uncoated surfaces before storing the motor away.
Corrosion protection
Lenze offers paints with different resistance characteristics for drive systems. Since the
resistance may be reduced when the paint coat is damaged, defects in paint work (e.g.
through transport or assembly) must be removed professionally to reach the required
corrosion resistance.
Mechanical installation
Provide for careful handling and avoid mechanical overload. During handling
neither bend components, nor change the insulation distances.
Electrical installation
Carry out the electrical installation according to the relevant regulations (e. g.
cable cross-sections, fusing, connection to the PE conductor). A dditional notes are
included in the documentation.
The Instructions contain notes concerning wiring according to EMC regulations
(shielding, earthing, filters and cable routing). The compliance with limit values
required by the EMC legislation is the responsibility of the manufacturer of the
machine or system.
Warning: The inverters are automation components which can be used in industrial
environment according to EN 61000-6-4. These products may cause radio
interference in residential areas. If this happens, t he operator may need to take
appropriate action.
Only plug in or remove pluggable terminals in the deenergised state!
Commissioning
If required, you have to equip the system with additional monitoring and
protective devices in accordance with the respective valid safety regulations (e. g.
law on technical equipment, regulations for the prevention of accidents).
Before commissioning remove transport locking devices and keep them for later
transports.