Parameter Name / value range / [default seng] Info
79 Torque limit reached (from version 02.00) TRUE if torque limit has been reached or exceeded. Otherwise FALSE.
Seng "Posive torque limit" in 0x60E0.
Seng "Negave torque limit" in 0x60E1.
81 Error of analog input 1 acve TRUE if the monitoring of the input signal at the analog input 1 has
responded. Otherwise FALSE.
This trigger is set as a funcon of the following sengs:
Monitoring threshold 0x2636:008 (P430.08)
Monitoring condion 0x2636:009 (P430.09)
The seng of the Error response in 0x2636:010 (P430.10) has no eect
on this trigger.
4Analog input 1 ^ 409
82 Error of analog input 2 acve TRUE if the monitoring of the input signal at the analog input 2 has
responded. Otherwise FALSE.
This trigger is set as a funcon of the following sengs:
Monitoring threshold 0x2637:008 (P431.08)
Monitoring condion 0x2637:009 (P431.09)
The seng of the Error response in 0x2637:010 (P431.10) has no eect
on this trigger.
4Analog input 2 ^ 413
83 Load loss detected TRUE if actual motor current < threshold for load loss detecon aer
delay me of the load loss detecon has elapsed. Otherwise FALSE.
Display of the present motor current in 0x6078 (P103.00).
Seng Threshold in 0x4006:001 (P710.01).
Seng Deceleraonin 0x4006:002 (P710.02).
4Load loss detecon ^ 277
102 Sequence suspended (from version 03.00) Status signal of the "sequencer" funcon:
TRUE if the sequence is currently suspended.
4Sequencer ^ 325
103 Sequence done (from version 03.00) Status signal of the "sequencer" funcon:
TRUE if the sequence is completed (nal segment has been passed
through).
4Sequencer ^ 325
104 Local control acve TRUE if local keypad control ("LOC") acve. Otherwise FALSE.
105 Remote control acve TRUE if remote control ("REM") via terminals, network, etc. acve. Oth-
erwise FALSE.
106 Manual setpoint selecon acve TRUE if manual setpoint selecon ("MAN") via keypad acve. Otherwise
FALSE.
Selecon of the trigger for the "Acvate keypad setpoint" funcon in
0x2631:016 (P400.16).
107 Automac setpoint selecon acve TRUE if automac setpoint selecon ("AUTO") via terminals, network,
etc. acve. Otherwise FALSE.
201 Internal value (from version 05.00) Internal values of the manufacturer.
202 Internal value (from version 05.00)
203 Internal value (from version 05.00)
204 Internal value (from version 05.00)
205 Internal value (from version 05.00)
206 Internal value (from version 05.00)
Flexible I/O conguraon