Operating instructions i550 motec frequency inverter | 9
© 03/2022 · EN · www.Lenze.com
Mechanical installation
E
E
H1
H
B
B1
E
E
Dimensions and assembly
NOTE
The specied installation clearances are minimum dimensions to ensure a sucient air
circulation for cooling purposes. They do not take into account the bending radii of the
connecting cables.
Inverter
Rated power Weight H B T H1 B1
Screws
E
[kW] [kg] [mm] [mm] [mm] [mm] [mm] [mm]
3-phase mains connection 230/240 V devices
I55AMxxxC 0.37 ... 1.1 kW 3.2 219 265 128 182 90 4x M5 >50
I55AMxxxC 1.5 ... 3 kW 3.8 219 265 152 182 90 4x M5 >50
3-phase mains connection 400/480 V devices
I55AMxxxF 0.37 ... 2.2 kW 3.2 219 265 128 182 90 4x M5 >50
I55AMxxxF 3 ... 5.5 kW 3.8 219 265 152 182 90 4x M5 >50