Technical data
General d ata and operating conditions
4
19
Lenze BA 33.0006 5.1
4 Technical data
4.1 General data and operating conditions
General data
Conformity
CE 2006/95/EC Low-Voltage Directive
Approvals
UL ANSI/UL 1004-1
ANSI/UL 1004-6
Rotating Electrical Machines
Servo and Stepper Motors
CSA CSA-C22.2 No. 100 Motors and Generators
EAC

(TR CU 020/2011)
Electromagnetic
compatibility of technical
means
Eurasian Conformity
TR CU: Technical Regulation of
Customs Union

(TR CU 004/2011)
On safety of low voltage
equipment
Eurasian Conformity
TR CU: Technical Regulation of
Customs Union
Protection of persons and devices
Enclosure IEC/EN 60034-5
See nameplate
Degrees of protection only apply to horizontal installation
All unused connectors must be closed with protection
covers or blanking plugs.
Temperature class F (155 °C)
IEC/EN 60034-1
Exceedance of the temperature limit weakens or destroys
the insulation
Permissible voltage As specified by limiting curve A of the pulse voltage from
IEC / TS 60034-25:2007 (corresponds to IVIC
C/B/B@500V)
EMC
Noise emission
IEC/EN 61800-3 Depending on the controller, see documentation for the
controller.
Noise immunity
Operating conditions
Ambient conditions
Climatic
Transport IEC/EN 60721-3-2 2K3 (-20 °C ... +70 °C)
Storage IEC/EN 60721-3-1
1K3 (-20 °C ... +60 °C) < 3 months
1K3 (-20 °C ... +40 °C) > 3 months
Operation IEC/EN 60721-3-3
3K3 (-20 °C ... +40 °C) MC
A, MCS,
MDKS
Without brake
3K3 (-15 °C ... +40 °C) MC
M, MQA
3K3 (-10 °C ... +40 °C) With brake
3K3 (-15 °C ... +40 °C) With blower
> +40 °C With power reduction, see
catalogue
Site altitude < 1000 m amsl - without power reduction
> 1000 m amsl < 4000m amsl with power reduction, see
catalogue
Humidity Relative humidity 85 %, without condensation
Electrical
The motor connection type depends on the controller
Length of the motor cable
See inverter instructions
Length of cable for speed feedback
Mechanical
IEC/EN60721-3-3 3M6

Related product manuals