Electrical installation
Plug connectors
Feedback system
6
31
Lenze • BA 33.0006 • 5.1
6.3.3 Feedback system
Resolver (external view of poles)
Contact Name Meaning M23
1
2
+Ref
-Ref
Transformer windings
(reference windings)
3 +VCC ENP Supply: electronic nameplate
1)
4
5
+COS
-COS
Stator windings cosine
6
7
+SIN
-SIN
Stator windings
Sine
8
9
Not assigned
10 Shield Encoder housing shield
11
12
+KTY
-KTY
Thermal detector KTY
Incremental encoder / sin/cos absolute value encoder Hiperface (external view of poles)
Contact Name Meaning M23
1 B Track B / + SIN
2
3
A
A
TrackAinverse/ -COS
Track A / + COS
4
5
+U
B
GND
Supply +
Mass
6
7
Z
Z
Zero track inverse / - RS485
Zero track / + RS485
8 Not assigned
9 B TrackBinverse/-SIN
10 Shield Encoder housing shield
11
12
+KTY
-KTY
Thermal detector KTY
Sin/cos absolute value encoder with EnDat interface (external view of poles)
Contact Name Meaning M23
1 U
P
sensor Supply U
P
sensor
2
3
Not assigned
4 0 V sensor 0 V sensor supply
5
6
+KTY
-KTY
Thermal detector KTY
7 +U
B
Supply + / +VCC E NP
1)
8
9
Cycle
Cycle
Clock pulse EnDat interface
Clock pulse inverse EnDat
interface
10 GND Mass
11 Shield Encoder housing shield
12
13
B
B
Track B
Track B inverse
14 Data Data EnDat interface
15
16
A
A
Track A
Track A inverse
17 Data Data inverse EnDat interface
1) Only for versions with electronic nameplate ENP.