6.2 EMC-compliant wiring
The EMC-compliant wiring of the motors is described in detail in the Operating
Instructions for the Lenze controllers.
Use of metal EMC cable glands with shield connection.
Connect the shielding to the motor and to the device.
6.3 Plug connectors
The connectors comply with vibration and shock class 3M6 as specified in
IEC/EN60721-3-3. This applies to all power, encoder and fan connector boxes.
Stop!
Cable connectors with screwed connection:
Always use with the O-rings supplied.
Cable connectors with a SpeedTec bayonet lock:
Remove O-ring and dispose of it.
When connecting the cable connector to the motor connector, make sure that the aids
toorientation (pos. 1) arefacingeachother.Only then trouble-free operationisensured.
Tighten the box nut of the cable connectors!
Never disconnect cable connectors whilst voltage is being applied! Otherwise the
connector may be destroyed! Inhibit the inverter before disconnecting the plugs!