14. SPECIFICATIONS
AC Input
Voltage range, rated 100-230 Vac
Voltage range, operating 90-264 Vac
(< 100 Vac: reduced power)
Frequency, rated 50-60 Hz
Frequency, operating 45-65 Hz
Phase Single-phase
Current, maximum 27790, 27800, 28110, 28120, 27940, 27950: 8A
28000, 28230: 12A
Protection Current limit, surge, transient, under voltage
DC Output
Voltage, nominal 27790, 27800, 28000: 48 Vdc
29180: 42 Vdc
28110, 28120, 28230: 36 Vdc
27940, 27950: 24 Vdc
Voltage, maximum 27790, 27800, 28000: 72 Vdc
29180: 63 Vdc
28110, 28120, 28230: 54 Vdc
27940, 27950: 36 Vdc
Voltage, minimum start-up 10 Vdc
Power 28110, 28120: 640 W
27790, 27800, 27940, 27950: 700 W
28230: 950 W
29180: 1000 W
28000: 1050 W
Current, rated 27790, 27800: 13 A
28110, 28120: 14.5 A
28000: 19.5 A
28230, 29180: 21 A
27940, 27950: 25 A
Current, maximum 27790, 27800, 28110, 28120: 14.5 A
28000, 28230, 29180: 21A
27940, 27950: 25 A
Battery types Wet/flooded, AGM, gel deep-cycle lead-acid; lithium-ion; custom. (See
Section 3 for additional details.)
Protection Current limit, short circuit, reverse polarity, under voltage, over voltage,
wrong battery voltage
LEDs Charge Complete (green),
Charge Status (yellow),
Fault (red)
Lockout Control Optional. Pulls down to battery neg (-) when active. See Section 7 for
options and additional details.
Battery Temp Sensor Optional
Remote LEDs Optional
Mechanical
Dimensions & mounting
pattern See Figures 2.2 and 2.3
Weight (approximate) Case #1: 9 lbs (4.1 kg), Case #2: 12 lbs (5.5 kg)
Cooling Natural convection (no fan)
AC connector IEC 60320 C16 inlet with cord clamp
Mounting Shelf, wall, bulkhead, threaded steel rod (with optional handle), hook
(with optional handle). See Figure 2.1 for additional details.
Handle Optional
Environmental
Enclosure rating IP66, NEMA 4
Operating temperature -25º C to 60º C (-13º F to 140º F). See datasheet for temperatures and
mounting orientations where power reduction occurs.
Storage temperature -40º C to 85º C (-40º F to 185º F)