Functions
Leuze electronic MLC 530 22
In doing so, the receiver automatically applies a tolerance area of one beam on both sides of a taught fixed
object, thereby expanding the movement area of the object by + 1 beam. On the borders of the blanked
object, the resolution is reduced correspondingly by 2 beams.
Activation of the function
Select operating mode 4 or 6 (see chapter 7 „Electrical connection“).
Figure 4.1: Fixed blanking: mechanical locks prevent side access to the protective field
Figure 4.2: Fixed blanking: prevention of “formation of shadows”
Teaching of fixed blanking areas
Teaching protective field areas with fixed or floating blanking is performed via a key switch in the following
steps:
Mount all objects to be blanked in the protective field in the locations at which they are to be blanked.
Press the teach key switch and release it within 0.15 s and 4 s.
The teach event begins. LED 3 flashes blue.
Press the teach key switch again and release it within 0.15 s and 4 s.
The teach event ends.
LED3 illuminates blue if at least one beam area is blanked.
All objects have been correctly taught.
WARNING
Reduced resolution during beam blanking may result in serious injury!
Take the reduced resolution into account when calculating the safety distance (see chapter 6.1.1
„Calculation of safety distance S“).
The “Fixed blanking” function can be combined with the “Floating blanking” function (see
chapter 4.7.2) and the “Reduced resolution” function (see chapter 4.7.4) (see chapter 7.5
„Operating mode 3“).