EasyManua.ls Logo

Leuze electronic MLC 530 - Dimensional Drawings: Accessories

Leuze electronic MLC 530
97 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
Leuze electronic MLC 530 88
Table 14.8: Additional dimensions for calculating the effective protective field height
14.3 Dimensional drawings: accessories
Figure 14.2: BT-L mounting bracket
Figure 14.3: BT-Z parallel bracket
The specified response times apply for operating modes 1, 2 and 3 (function group FG2). In op-
erating mode 3 (function group FG1, DoubleScan), the specified value doubles. In operating
modes 4 and 6 (MaxiScan), the response time always has a fixed value: 100 ms.
R = resolution B C
14 mm 0 mm 52 mm
20 mm 1.5 mm 48 mm
30 mm 13 mm 49 mm
40 mm 19 mm 43 mm
90 mm 44 mm 18 mm
39
16
29
12
R10
R3.1
4
R6
R3.1
R10
30
12
R3.1
18.4
31.7
73
61
6.2
6.2
R3.1
R10
R10
22
10
R3.1
10.8
4
25
12.1

Table of Contents