Electrical connection
Leuze electronic MLC 530 59
7.4 Operating mode 2
The following functions can be selected via external wiring:
Fixed blanking can be taught without size tolerance, see chapter 4.7.1 „Fixed blanking“.
Linkage of electronic safety-related switching outputs possible, see chapter 4.6.2 „Linking of elec-
tronic safety-related switching outputs“.
Linkage of contact-based safety-related switching outputs in addition to linkage of electronic safety-
related switching outputs possible, see chapter 4.6.1 „Contact-based safety circuit“.
The functions listed can be combined (see table 7.6).
Permanent settings which cannot be changed by control signals:
Internal start/restart interlock deactivated
SingleScan selected
Table 7.6: Pin assignment operating mode 2
Teach blanking by opening the bridge between pin 1 and pin 4 with a teach key switch and ap-
plying a voltage of +24 V to pin 1 and a voltage of 0 V to pin 4 (see table 7.5).
Pin Linking of electronic
safety-related switch-
ing outputs
Teaching the blanking (open
bridge, apply voltage)
Fixed blanking and linkage of
electronic safety-related switch-
ing outputs
1 (IO1) Bridge to pin 4 (IN4) +24 V
3 (IN3) OSSD1 from the
upstream device
Normal closed contact between
electronic safety-related switch-
ing outputs and device
4 (IN4) Bridge to pin 1 (IO1)
8 (IN8) OSSD2 from the
upstream device
0 V Normal closed contact between
electronic safety-related switch-
ing outputs and device
2 0 V 0 V 0 V
7 +24 V +24 V +24 V
5 OSSD1 OSSD1 OSSD1
6 OSSD2 OSSD2 OSSD2