Mounting
Leuze electronic MLC 530 35
1 Safety sensor
2 Danger zone
3Floor
a Height of the point of operation
b Height of the upper beam of the safety sensor
Figure 6.1: Additional distance to the safety distance when reaching over and under
Table 6.1: Reaching over the vertical protective field of electro-sensitive protective
equipment(excerpt from EN ISO 13855)
a
3
C
RO
KxT
b
1
2
S
RO
Height a of
the point of
operation
[mm]
Height b of the upper edge of the protective field of the electro-sensitive protective equip-
ment
900 1000 1100 1200 1300 1400 1600 1800 2000 2200 2400 2600
Additional distance C
RO
to the danger zone [mm]
2600 000000000000
2500 400 400 350 300 300 300 300 300 250 150 100 0
2400 550 550 550 500 450 450 400 400 300 250 100 0
2200 800 750 750 700 650 650 600 550 400 250 0 0
2000 950 950 850 850 800 750 700 550 400 0 0 0
1800 1100 1100 950 950 850 800 750 550 0 0 0 0
1600 1150 1150 1100 1000 900 850 750 450 0 0 0 0
1400 1200 1200 1100 1000 900 850 650 0 0 0 0 0
1200 1200 1200 1100 1000 850 800 0 0 0 0 0 0
1000 1200 1150 1050 950 750 700 0 0 0 0 0 0
800 1150 1050 950 800 500 450 0 0 0 0 0 0
600 105095075055000000000