Limited Warranty
LEVITON LIGHTING CONTROL DIVISION of
Leviton Manufacturing Co Inc. warrants its Dimmer
Systems and Controls to be free of material and work-
manship defects for a period of two years after system
acceptance or 26 months after shipment, whichever
comes first. This Warranty is limited to repair or replace-
ment of defective equipment returned Freight Pre-Paid to
Leviton Lighting Control Division at 20497 SW Teton
Ave., Tualatin, Oregon 97062, USA. User shall call 1-
800-959-6004 and request a return authorization number
to mark on the outside of the returning carton, to assure
that the returned material will be properly received at
Leviton. All equipment shipped back to Leviton must be
carefully and properly packed to avoid shipping damage.
Replacements or repaired equipment will be returned to
sender freight prepaid, F.O.B. factory. Leviton is not
responsible for removing or replacing equipment on the
job site, and will not honor charges for such work.
Leviton will not be responsible for any loss of use time or
subsequent damages should any of the equipment fail
during the warranty period, but agrees only to repair or
replace defective equipment returned to its plant in
Tualatin, Oregon. This Warranty is void on any product
that has been improperly installed, overloaded, short cir-
cuited, abused, or altered in any manner. Neither the
seller nor Leviton shall be liable for any injury, loss or
damage, direct or consequential arising out of the use of
or inability to use the equipment. This Warranty does not
cover lamps, ballasts, and other equipment which is sup-
plied or warrantied directly to the user by their manufac-
turer. Leviton makes no warranty as to the Fitness for
Purpose or other implied Warranties.
For Technical Assistance Call:
1-800-959-6004
www.nsicorp.com
www.leviton.com
Introduction
1
2
5
6
For best results using the Dimensions 8000 Architectural
Lighting Controller, Follow these recommendations:
1. Plan the system before beginning the installation
2. Terminate the wiring
3. Test the wiring
4. Connect dimmer cabinets
5. Check Voltages
6. Power up the Stations
7. Program each Station
Assign unique network ID numbers to stations.
Check the proper operation of each station as it is
installed when multiple stations are involved.
8. Install all Stations
Note: If the lighting control fails or becomes sporadic,
first check the wiring or network ID.
1. To be installed and/or used in accordance with
appropriate electrical codes and regulations.
2. To be installed by a qualified Electrician.
3. DO NOT CONNECT line voltage wires to low volt-
age terminals.
4. For the best lamp life, lamp manufacturers recom-
mend their fluorescent lamps should be operated at
full brightness for a minimum of 100 hours before dim-
ming is permitted. For best results, lamp brands and
types should not be intermixed on a circuit.
5. Disconnect power when servicing the dimmer, fix-
ture or when changing lamps.
6. Indoor use only.
7. TO AVOID FIRE, SHOCK OR DEATH: TURN OFF
POWER AT MAIN CIRCUIT BREAKER OR FUSE
AND TEST THAT THE POWER IS OFF BEFORE
WIRING!
Warnings
Terminating the Wiring
Luma-Net® III
Control Stations can be located up to 2000 ft. from
the dimming cabinet. Luma-Net® is wired Daisy
Chained, station to station. For applications where
runs become too long, or a star configuration is
desired, a Hub can be used.
The cable should not pass near any source of electri-
cal noise such as fluorescent circuits or motor wiring.
Avoid close proximity to any AC wiring
All control/power wiring must be in conduit.
Luma-Net® Wire Recommendations
1. Use RS485 compatible cable for communications.
It is recommended that a cable with 2 Twisted Pair,
24 AWG (min.), stranded conductors be used. The
spare pair is for future uses.
2. Capacitance of wire shall be 15pF/ft. or less.
3. Normal Impedance of wire shall be between 100-
120 ohms.
4. Drain/Shields to be tied together, insulated and
grounded at one point only.
We strongly recommend the use of either Belden
9829, Belden 8102 or Belden 9729 for the Luma-
Net® wire runs.
5. A second pair of stranded wire is required for the
power.
D4200 CONTROL STATION
PRESET SELECT STATION
C
12
18
15
16
17
13
14
6
9
10
11
7
8
3
4
5
1
2
A
B
DMX
CANCEL
LUMANET
CLEAR
PHASE LOSS
AUXILIARY
FULL BRIGHT
COMMUNICATION PORTS
FAN
SAVE
FULL
SELECT
BRIGHT
a-2000D
Note: a-2000D Cabinet can be in the
middle of a daisy chain
If a remote DC power supply is used and you have multi-
ple Luma-Net® runs, all DC common wires must be
joined at the power supply.
At the last control station or dimmer cabinet on both ends
of run, a small jumper wire must be run from the terminal
labeled “Rem-” to the terminal marked “Term” on that last
station. This jumper wire properly terminates the digital
communications lines at both ends of the line.
Wire the Phoenix/Luma-Net Connector
1. Connect leads per wiring diagram as illustrated on page
6.
2. Twist strands of each lead tightly (making sure that
there are no stray strands) and push firmly into appropri-
ate plug connector location.
3. Tighten the screws on the plug connector-making sure
that no bare conductor is showing.
4. Tie the Drain/Shield wires together and insulate using a
small piece of heat shrink tubing.
5. Install termination jumpers as required. Remember a
termination jumper is required at the two ends of the
Luma-Net® run.
REM+
REM -
COM
TERM
LOCK
+V
1
2
3
4
5
6
Up to 1 #12AWG
2#12AWG
2#12AWG
Up to 1 #12AWG
Drain/Shield - Insulated and tied together
(Ground at one point only-
probably an end)
Red
(+V )
Black (Common)
5
6
1
2
3
4
Phoenix/Luma-Net Connecto
r
Luma-Net® Wire Connections
Ceiling Mount IR for
D4200 and D8000
Cat #
D42IR-RSW
D42IR-RFW
KIRRF-00W
KIRRS-00W
3 4
a-2000D
PRESET SELECT STATION
17
16
18
10
11
14
13
15
12
5
8
7
9
6
B
2
4
3
C
1
A
D4200 CONTROL STATION
LUMANET
DMX
CLEAR
CANCEL
FAN
COMMUNICATION PORTS
FULL BRIGHT
AUXILIARY
PHASE LOSS
BRIGHT
SELECT
FULL
SAVE
LUMA-NET III HUB
a-2000D
PRESET SELECT STATION
17
16
18
10
11
14
13
15
12
5
8
7
9
6
B
2
4
3
C
1
A
D4200 CONTROL STATION
LUMANET
DMX
CLEAR
CANCEL
FAN
COMMUNICATION PORTS
FULL BRIGHT
AUXILIARY
PHASE LOSS
BRIGHT
SELECT
FULL
SAVE
LIT-32686-000
Rev A 3/2004

Other manuals for Leviton D4200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Leviton D4200 and is the answer not in the manual?

Leviton D4200 Specifications

General IconGeneral
Voltage120 VAC
Neutral RequiredYes
ColorWhite
Product TypeDimmer
Load TypeIncandescent
Wiring3-wire
Standards and CertificationsUL
Voltage Rating120V
Maximum Load600W Incandescent
Operating Temperature32°F to 104°F (0°C to 40°C)
Warranty5 Years

Related product manuals