Auto Sequencing Mode
The DDS 6000 dimmers can be configured to perform stand alone Automatic Sequencing in place of Auto Lamp Test. This is
useful for lighting displays and show windows. The four channels will automatically fade from one to another in a preprogrammed
pattern and time selected by the front panel dipswitch whenever front panel dipswitch #8 is up and no multiplex signal is detected.
The Analog control input will continue to operate while the dimmer is sequencing.
To enable Automatic Sequencing Mode move the switch on the internal configuration dipswitch #2 to OFF.
Front panel Dipswitch sequence settings. (not internal dipswitch)
STEP TIME SWITCH 1,2,3 PATTERN SWITCH 4,5,6
1 SECOND OFF,OFF,OFF 2 CHAN BUILD OFF,OFF,OFF
3 SECOND ON,OFF,OFF 3 CHAN SEQUENCE ON,OFF,OFF
5 SECOND OFF,ON,OFF 3 CHAN BUILD OFF,ON,OFF
10 SECOND ON,ON,OFF 2&4 CHAN ALT ON,ON,OFF
15 SECOND OFF,OFF,ON 4 CHAN SEQUENCE OFF,OFF,ON
30 SECOND ON,OFF,ON 4 CHAN BUILD ON,OFF,ON
45 SECOND OFF,ON,ON 4 CHAN BUILD + OFF,ON,ON
60 SECOND ON,ON,ON 4 CHAN RANDOM ON,ON,ON
Dipswitch # 7 on causes all above sequences to ping-pong.
DDS 6000 DIMMER PACK
Software Revision 1.0 and above, Version C, UL Versions
8 NSI CORPORATION