15
If your fan is not connecting to your My Leviton app, the status
light can be used as a diagnostic tool. Press the top rocker for
at least 2 seconds but less than 7 seconds and release. The
light will blink a diagnostic code for two seconds:
Yellow - the fan controller is not connected to Wi-Fi.
Red - the fan controller is connected to Wi-Fi but not the
My Leviton cloud.
Alternating green/yellow - the fan controller is connected
to Wi-Fi and My Leviton cloud but has been unable to set
the time from the internet.
Green - the fan controller is connected to Wi-Fi and My
Leviton cloud and is working properly.
Diagnostic status light
Reset
To reset the fan controller to
factory settings:
1. Hold the top of the paddle for
a total of 14 seconds.
2. After the first 7 seconds the
LED turns amber. Continue
to hold.
3. After a total of 14 seconds, the status light will quickly flash
red/amber.
4. Release the top of the paddle and it will reset.