EasyManua.ls Logo

Lewitt LCT 540 S User Manual

Lewitt LCT 540 S
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
QUICKSTART GUIDE
// LCT 540 S
// User Interface
Status indicator //
Illuminated white: standard operation
Flashing red: clipping occurs
Not illuminated: key-lock active
Illuminated red: Automatic Attenuation active
Flashing white and red: Clipping History active
Low-cut indicator // Use left pushbutton to change the low-cut
settings. Low-cut lters eliminate unwanted low-frequency sounds,
compensate the proximity effect and reduce structure-borne noise.
Pre-attenuation indicator // Use right pushbutton to select the pre-
attenuation. Use this setting to avoid clipping when recording very loud
sound sources.
Pushbutton functions
Key-lock // Hold the center pushbutton for more than 2 seconds to
activate the key-lock mode. Now all pushbuttons are locked until you
press any button for 2 seconds again.
Clipping History // Hold the left pushbutton for more than 2 seconds
to enter Clipping History. If the status indicator ashes white, no clipping
occurred. If the status indicator ashes red/white, clipping occurred.
The illuminated pre-attenuation symbols show at which pre-attenuation
setting the clipping occurred. Press any button for more than 2 seconds
to exit Clipping History. Once you exit the Clipping History or remove 48V
the history is deleted.
Automatic Attenuation // Hold the right pushbutton for more than
2 seconds to activate Automatic Attenuation and the status indicator turns red. In this mode, the microphone adjusts the
attenuation setting automatically when clipping occurs. The adjustment produces an audible sound. Therefore, this feature is
intended to be used for recording test runs only and to set all mics to the correct attenuation. It is not recommended to be used
during actual recordings. Deactivate by pressing any button again for more than 2 seconds; the status indicator turns white
again.
// Perfect Match technology
Every single LCT 540 S undergoes a series of measurements followed by adjustment of the polarization voltage to achieve
the same sensitivity at 1 kHz in every LCT 540 S ever produced.
// Getting started
1 Attach the LCT 40 SHx shock mount to a sturdy microphone stand.
2 Place the LCT 540 S in the shock mount and secure it by fastening the threaded nut.
3 The illuminated user interface indicates the front of the microphone. Point it towards the sound source.
4 Connect the LCT 540 S via standard 3-pin XLR cable to an audio interface, microphone preamplier,
or mixing console, capable of providing 48 V phantom power (P48).
5 Mute your microphone channel before you turn the phantom power on, as it produces a short switch-on sound.
6 Set the input gain on your audio interface, mixing console, preamp, etc. accordingly.
7 Adapt to the sound source and recording environment using low-cut and pre-attenuation settings.
8 Use the supplied LCT 50 PSx pop lter when recording vocals or spoken word to reduce unwanted plosives.
9 To ensure best sound quality, do not cover any part of the grille.
10 You are ready to go!
LEWITT
®
Burggasse 79
1070 Vienna
Austria
www.lewitt-audio.com
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired operation.
1
2
3
4
REDISCOVER SOUND
EXPLORE ALL DETAILS
CUTTING-EDGE CONDENSER MICROPHONE
FOR ULTRA-DETAILED SONIC IMAGES
READ THE
FULL MANUAL!
LEARN EVERYTHING ABOUT YOUR LCT 540 S
www.lewitt-audio.com/manuals/LCT-540-S.pdf
Question and Answer IconNeed help?

Do you have a question about the Lewitt LCT 540 S and is the answer not in the manual?

Lewitt LCT 540 S Specifications

General IconGeneral
TypeCondenser
Polar PatternCardioid
Frequency Response20 Hz - 20 kHz
Max SPL136 dBSPL
Sensitivity25 mV/Pa (-32 dBV)
Impedance50 Ohms
Weight430 g / 15.2 oz
Equivalent Noise Level7 dB (A)
Current Consumption3.1 mA
Power Supply48 V Phantom Power
Supply Voltage48V
ConnectorXLR
Signal-to-Noise Ratio87 dB (A)

Summary

User Interface Overview

Status Indicator Meanings

Details the different states of the status indicator light (white, red, not illuminated).

Low-Cut Indicator and Function

Explains how to use the low-cut filter to reduce unwanted low-frequency sounds.

Pre-Attenuation Indicator and Function

Describes using pre-attenuation to avoid clipping with very loud sound sources.

Pushbutton Functions Explained

Covers key-lock mode, clipping history access, and automatic attenuation.

Perfect Match Technology

Getting Started with LCT 540 S

Attach Shock Mount

Instructions for attaching the LCT 40 SHx shock mount to a microphone stand.

Mount Microphone Securely

Placing and securing the LCT 540 S into the shock mount.

Microphone Orientation

Positioning the microphone correctly towards the sound source.

Connect via XLR Cable

Connecting the microphone to an audio interface or mixer using an XLR cable.

Phantom Power Activation

Muting the channel before turning on 48V phantom power.

Set Input Gain Level

Adjusting the input gain on your audio interface, mixer, or preamp.

Utilize EQ and Attenuation

Using low-cut and pre-attenuation settings for sound and environment adaptation.

Use Pop Filter for Vocals

Recommends using the pop filter for vocals to reduce plosives.

Maintain Grille Clarity

Advice to not cover the grille for optimal sound quality.

Ready for Operation

Confirmation that the microphone setup is complete and ready to use.

Related product manuals