EasyManua.ls Logo

Lexicon MC-12 V3.0 - SERIAL COMMUNICATIONS PROTOCOL DEFINITION REV 1-5 - Clear All Parameter Notifications Command; Clear All Parameter Notifications Packet Description; Get System Status Command (MC-12); Get System Status Command Packet Description

Lexicon MC-12 V3.0 - SERIAL COMMUNICATIONS PROTOCOL DEFINITION REV 1-5
94 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Lexicon, Inc.
MC-12 Serial Communications Protocol Printed on: 08/18/03
© 2003 Lexicon, Inc. All rights reserved. 44 of 94
Data Type: Null (0x00) terminated ASCII string.
Max Length: 21 (20 characters plus terminating Null)
7.3.44 MC-12 Clear All Parameter Notifications (MC-12)
Request to the MC-12 to disable all MC-12 parameter notifications.
7.3.44.1 Command Packet Description
Application Header:
Command MC_CMD_CLEAR_ALL_PARAM_NOTIFICATIONS 0x3D
Data Count 0 0x00
Application Data:
N/A
7.3.45 MC-12 Get System Status (MC-12)
Request to MC-12 for its current system status. MC-12 will respond with “System Status Packet”.
7.3.45.1 Command Packet Description
Application Header:
Command MC_CMD_GET_SYS_STATUS 0x3E
Data Count 0 0x00
Application Data:
N/A
7.3.45.2 System Status Response Packet
Application Header:
Command MC_RESP_SYS_STATUS 0x94
Data Count 10 0x0A
Application Data:
Data[0] System Volume nn
Data[1] Current Input nn
Data[2] Current Effect Id nn
Data[3] Current Input Sample Rate nn
Data[4] Current Input Format nn
Data[5] Mute Active nn
Data[6] Effect Bypass nn
Data[7] Left/Right Balance nn
Data[8] Front/Back Balance nn
Data[9] Video Sync nn
7.3.45.3 Data Description
System Volume:

Table of Contents