Lexicon MC-12HD Serial Communications Protocol
7.3.13 MC-12HD Set Parameter Value by Id, No Run
MC-12HD Set Parameter by Id command sets the parameter value equal to the value sent in the
command packet and does not run the appropriate functional changes associated with changing the
given parameter.
7.3.13.1 Command Packet Description
Application Header:
Command MC_CMD_SET_PARAM_VALUE_BY_ID_NO_RUN 0x37
Data Count 24 0x18
Application Data:
Data[0] ParamId(LSB) nn
Data[1] ParamId(MSB) nn
Data[2] ParamType nn
Data[3-23] Value[0 -20]
nn nn
nn…
7.3.13.2 Data Description
Same as
Parameter Set Data Description
7.3.14 MC-12HD Get Unit Configuration
Requests the current MC-12HD unit configuration. MC-12HD will respond with “Unit Configuration
Packet”. The HOST should use this information to determine if any information saved by the HOST is
current.
7.3.14.1 Command Packet Description
Application Header:
Command MC_CMD_GET_CONFIG 0x38
Data Count 0 0x00
Application Data:
N/A
20