39
Lexicon PCM 90 MIDI Implementation Details
data in a bank dump. Packets are sent as follows:
Header and label information (68 byte); Pause; 1st
effect (2334 byte); Pause; 2nd-50th effects with
pauses. Final effect data includes EOX
27 1B MIDI automation mode 1 n 0 =Off; 1=On
28 1C transmitted device ID
for automation 127 n 0 - 126 are specific target ID’s; 127 is a broadcast.
29 1D Tempo blink 1 y 0=On; 1=Off
30 1E Global tempo value 360 y 40-400 BPM in 1 beat increments.
31 1F Dig In status 0 n No effect when transmitted.
32 20 Selects display of
digital error 5 n 0=Validity; 1=Confidence; 2=Slip Sample; 3=CRC;
4=Parity
33 21 Transmitted SCMS
selection 2 n 0=No Copy; 1=Single Copy; 2=Multi Copy
34 22 Transmitted emphasis
selection 2 n 0=No Emphasis; 1=Emphasis; 2=Pass Thru
35 23 Tempo source 1 y 0=Internal; 1=MIDI
36 24 Analog output level 1 n 0=-10 dBu; 1=+4 dBu
37 25 Bypass controller assign 120 y 0=No Assigment; 1-118=MIDI controllers; 119=Foot
Sw 1; 120=Foot Sw 2.
38 26 Custom 1 controller
assign 118 n
39 27 Custom 2 controller
assign 118 n
40 28 Custom 3 controller
assign 118 n
41 29 Custom 4 controller
assign 118 n
42 2a Keyview Enable 1 y
43 2b KeyWord ID 0 n No effect.