6
LexiconPCM 90 MIDI Implementation Details
0x01 Bank Dump
This is a bidirectional dump of an entire bank of effects. It is initiated from the front panel as a Bank Dump.
Byte # Byte Value Description Notes
1 F0 SysEx ID
2 06 Lexicon ID
3 08 PCM 90 ID
4 0iii iiii Device ID
5 0x1 Effect bulk Data
6 0iii iiii Bank # Source bank if sent by PCM 90; target bank if received by
PCM 90. See appendix for indices of banks.
7- 13 0iii iiii 7 Byte ASCII Bank Label
14- 24 0iii iiii 11 Byte ASCII Row Label 0
25- 35 ......... 11 Byte Row label 1
36- 46 ......... 11 Byte Row label 2
47-57 ......... 11 Byte Row label 3
58-68 ......... 11 Byte Row label 4
69-116918 xxxxxxxx 50 Single effect data packets
with checksums after each See Description of Nibble-ized Effet Data.
116919 0xF7 End of SysEx
Note that it is possible for a bank to be sparsely populated (for example when a user has only a small
number of effects saved in bank 4 or 5). It is important to check the validity bit in the Flags byte for each
effect. (See Single Effect Data for a description of the validity bit.)
Note that after a bank is received, a period of approximately 2 seconds is required for the PCM 90 to sort
and merge the banks.
Note also that for any effect to be successfully transmitted or received by the PCM 90, the supporting
algorithm must be present (not necessarily running) in the unit. Internal algorithms are always present,
whereas Card algorithms are only present if the card has been loaded. If an effects packet is transmitted
without the algorithm present, an error message is displayed. Such cases also cause special formatting
of the effects packet. See Single Effect Data for details. If an effects packet is received without the
algorithm present, an error message is displayed and the destination remains unchanged.