PCM 90 MIDI Implementation Details
Lexicon
Not all of system parameters are transmitted by SysEx Automation. Those which are transmitted are listed
in Appedix F.
Other MIDI Implementation Notes
MIDI Controller 32 is used for Bank Select. MIDI Controller 0 (normally the most-significant bits of Bank
Select) is ignored.
Program Change messages may be lost if they are sent to the PCM 90 before previous Program Change
messages are completed.
Controller Data may be sent at full MIDI speed, with no loss of data.
If a MIDI controller is mapped to drive an internal controller (ADJUST, Custom, Foot Pedal, Footswitch),
its value will be ‘pegged’ at the min/max values assigned in each preset. For example, if ADJUST is
mapped to Controller 1 and its minimum value is set to 10, any incoming controller value of 10 or below
will be treated as if a 10 had been received.