36. Check Tile Mode (Command: d z)
Checks the tile mode.
Transmission
[d][z][ ][Set ID][ ][Data][Cr]
Data FF: Checks Tile Mode
Acknowledgment
[z][ ][Set ID][ ][OK/NG][Data1][Data2][Data3][x]
Data 1 00: Tile Mode Off
01: Tile Mode on
Data 2 00 to 0F: tile column
Data 3 00 to 0F: tile row
* This feature may not be supported on some models.
37. Tile ID (Command: d i)
Sets the tile ID value of the product.
Transmission
[d][i][ ][Set ID][ ][Data][Cr]
Data 01 to E1: Tile ID 1 to 225
FF: Checks the Tile ID
* The data value cannot exceed the value of row x column.
Acknowledgment
[i][ ][Set ID][ ][OK/NG][Data][x]
* If you enter a value that exceeds the value of row x column
for the Data parameter, Ack becomes NG.
* This feature may not be supported on some models.
38. Natural Mode (In Tile Mode) (Command: d j)
To display the image naturally, the part of the image that
would normally be displayed in the gap between the monitors
is omitted.
Transmission
[d][j][ ][Set ID][ ][Data][Cr]
Data 00: Off
01: On
Acknowledgment
[j][ ][Set ID][ ][OK/NG][Data][x]
* This feature may not be supported on some models.
39. Energy Saving Settings (Command: f j)
Sets the Display Power Management feature.
Transmission
[f][j][ ][Set ID][ ][Data][Cr]
Data 00: Off
04: 1 minute
05: 3 minutes
06: 5 minutes
07: 10 minutes
Acknowledgment
[j][ ][Set ID][ ][OK/NG][Data][x]
* This feature may not be supported on some models.
40. Remote Control/Local Key Lock (Command: k m)
Adjusts the remote control/local key (front) lock.
Transmission
[k][m][ ][Set ID][ ][Data][Cr]
Data 00: Off (Lock Off)
01: On (Lock On)
* When the monitor is turned off, the power key works even in
On (01) mode.
Acknowledgment
[m][ ][Set ID][ ][OK/NG][Data][x]
* This feature may not be supported on some models.
41. Power On Delay (Command: f h)
Sets the schedule delay for when the power turns on (unit:
seconds).
Transmission
[f][h][ ][Set ID][ ][Data][Cr]
Data 00 to FA: min. 0 to max. 250 (seconds)
Acknowledgment
[h][ ][Set ID][ ][OK/NG][Data][x]
* The maximum value may differ depending on the model.