23
206-4322
EZ-Manager Wizard (Cont.)
(Continued from previous page)
RF Conguration
a) In the Media Type eld, use the Left/Right arrow keys to select RF.
b) In the Data Channel eld, use the Left/Right arrow keys to select the RF channel number
that will be used by the Pro:Centric server as its data channel. The Data Channel value can
be set from 1 to 135. *
IP Conguration
a) In the Media Type eld, use the Left/Right arrow keys to select IP.
Note: When you select “IP” as the Media Type, the default RF Data Channel and Signal
Strength/Quality elds are replaced with Server Address, IP Address, and IP Port elds.
b) The Server Address eld provides the option to specify the domain name of the Pro:Centric
server instead of the server’s IP address. Use the Left/Right arrow keys to select the desired
option—IP Address or Domain Name—for dening the server.
c) Depending on your selection in the previous step, either:
• Enter the Pro:Centric server IP address in the IP Address eld. The IP address must match
the IPv4 multicast address that is set in the Pro:Centric server.
• Enter the Pro:Centric server domain name in the Domain Name eld. Note that in order
for the domain name to be resolved to an IP address, there must be a DNS entry for the
domain name.
For each data entry eld: Use the arrow keys on the Installer Remote to select the eld and
press the Wheel (OK) button. Then, you can either use the number keys to direct enter data
values, or you can use the arrow keys to select the appropriate number(s)/alphanumeric
character(s) from the pop-up virtual keyboard displayed at the bottom of the screen. When
you are done, select Enter from the virtual keyboard, and then press the Wheel (OK) button.
d) Enter the Pro:Centric server port number in the IP Port eld. The port number must match the
port number that is set in the Pro:Centric server.
4. Once all elds are completed as required, you have two options:
• To save the data entered and exit the wizard, use the arrow keys to select the
X
button at the
top right of the screen, and then press the Wheel (OK) button. In the subsequent pop-up
conrmation window, select SAVE & EXIT, and then press the Wheel (OK) button once more.
The Pro:Centric application and/or E-Z Installation data will be downloaded to the TV at a later
time. This option is useful, in particular, if the Pro:Centric server has not yet been congured.
• To initiate a real-time download of Pro:Centric application and/or E-Z Installation data, use the
arrow keys to select SEARCH and press the Wheel (OK) button to verify the conguration
data provided in step 3. When the data is veried, the “SEARCH” button becomes a “NEXT”
button. Select NEXT and press the Wheel (OK) button to continue (see also note below).
Note: With RF conguration, Pro:Centric server data must be present on the RF channel
selected as the TV’s Data Channel in order for you to select “NEXT” (you will see a “data
channel found” message below the Signal Quality indicator). With IP conguration, Pro:Centric
server data must be present via the wired LAN cable connection in order for you to select
“NEXT” (you will see a “IP server found” message below the IP Port eld).
* PCS150R and later Pro:Centric servers do not support HRC or IRC cable channel frequencies.
(Continued on next page)