EasyManuals Logo

LG AMNH12GD4L0 Manuals

LG AMNH12GD4L0
254 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #201 background imageLoading...
Page #201 background image
- 201 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
6) Troubleshooting CH22
V
+
-
+-
+-
21
22
Max. C/T
C/T
Internal circuit
Over current (14A )
Initial current error
Malfunction of compressor
Blocking of pipe
Low voltage input
Refrigerant, pipe length, blocked,
Malfunction of current detection circuit.
(Open / Short)
The voltage of C01N Is 4.0Vdc(25A) .
Display
code
Title Cause of error Check point & Normal condition
Check Point
1. Check the power source.
2. Check the fan operation is right.
3. Check the current.
4. Check the install condition.
5. Check the internal circuit. (C/T, Diode, Resistor)
Troubleshooting Guide

Table of Contents

Other manuals for LG AMNH12GD4L0

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LG AMNH12GD4L0 and is the answer not in the manual?

LG AMNH12GD4L0 Specifications

General IconGeneral
BrandLG
ModelAMNH12GD4L0
CategoryAir Conditioner
LanguageEnglish

Related product manuals