EasyManua.ls Logo

LG GCWF1069QS1 - Page 33

LG GCWF1069QS1
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
33
SymptomCheck Point
1. DOOR OPEN
ERROR (dE)
1.Check Electric Wiring.
2.Check latch hook spring. (Cracked)
3.Check Door switch's Resistance.
4.Check Voltage of Door switch's connector.
Door switch
(Type1)
Result Remarks
(2) ~ (4) 700~1500˟
At 77
(25)
(3) ~ (4)65~85˟
At 77
(25)
(4) ~ (5)Infinity
(2) ~ (4) 120 Vac Voltage Input
O\P OZP
O[P OYP
Door switch
(Type2)
Result Remarks
(2) ~ (4) 700~1500˟
At 77
(25)
(3) ~ (4)
90~120˟
At 77
(25)
With Latch
Infinity Without Latch
(4) ~ (5)Infinity
(2) ~ (4) Voltage Input
120 Vac

Related product manuals