FHNW16606C0 [HN1616HC NK0], FHNW16809C0 [HN1639HC NK0]
Category Accessory Name Model Name Description Compatibility
Remote Controller Wired - RS3 (Standard III) PREMTW101 White O
Dry Contact
Simple PDRYCB000 1 input port, AC 220 - 240V O
Communication PDRYCB320 8 input port, For 3rd Party Thermostat (Analog Input) O
Integration Device
Remote Temperature sensor PQRSTA0 Room temperature sensor, NTC 10kΩ, include casing O
Group Control wire PZCWRCG3
Cable Assembly for group control (Y-type cable : 0.25m,
cable : 9.6m)
X
ETC
Extension wire PZCWRC1 Extension wire for IDU-wired remote controller (9.6m) O
2-Remo Control wire PZCWRC2
Y-type cable to connect additional Remote Controller as
slave
O
Wi-Fi Modem PWFMDD200 Device to use ThinQ app include connection cable O
Wi-Fi Extension cable PWYREW000 USB Extension cable : 10 m O
Meter Interface PENKTH000
Interface to connect 3rd-party heat and/or watt meter to
indoor unit by S0 or Modbus
O
Special Kit
Solar-Thermal Interface kit with
DHW T
ank
PHLLA* Limit Temperature : 96 ℃ O
Indoor Drain Pan
PHDPB For Hydro Unit X
PHDPC For Hydro Unit O
DHW tanks (Single coil)
OSHW-200F 200 L O
OSHW-300F 300 L O
OSHW-500F 500 L O
DHW tanks (Double coil) OSHW-300FD 300 L O
DHW tank kit
PHLTA For Hydro Unit (except for HN1639 NK3) O
PHLTC For Hydro Unit (HN1639 NK3) X
DHW sensor PHRSTA0 Included in DHW Tank kit O
Thermostatic Mixing valve
OSHA-MV 3/4” DN20 O
OSHA-MV1 1” DN25 O
3way valve OSHA-3V
Diverting valve between space heating and DHW heating
O
2nd Circuit Thermistor PRSTAT5K10
NTC 5kΩ sensor needed to control mixing circuit or if
3rd-party backup heater is used.
O
Backup Heater
HA061B E1 1Ø, 6kW (For Hydrosplit, HN1600MB NK0) X
HA061C E1 1Ø, 6kW (For Hydrosplit, HN1600MC NK1) X
HA063B E1 3Ø, 6kW (For Hydrosplit, HN1600MB NK0) X
HA063C E1 3Ø, 6kW (For Hydrosplit, HN1600MC NK1) X
Cover plate PDC-HK10 For IWT and Hydro Unit Type indoor units O
Note
■ O: Possible, X: Impossible, - : Unconfirmed or irrelevant, Embedded : Included with product.
■ Some advanced functions controlled by individual controller cannot be operated.
■ If there is a dif
ference in development time between the product and the remote controller, some functions cannot be operated.
■ Meter Interface cannot be connected at the same time with 3rd-party controller.
■ * : It includes double-sensor for solar tank. The collector sensor (PT1000) needs to be supplied locally.
■ If you need more detail, please refer to the Control(BECON) PDB or the manual of product.
(
http://partner.lge.com > Select Y
our Region : Home> Doc.Library> Product > Control(BECON)).
Hydro Unit
3. Accessory Compatibility List
Product Data
3-1