INSTALLATION
INSTRUCTION
Step6:
DRAIN
LINE
CONNECTION
1
2
If
the
end
of
drain
hose
does
not
fit
to
the
drain
line,
use
a
piece
ofrubber
connector(not
supplied)
that
must
be
resistant
to
heat
and
detergent
and
may
be
obtained
from
a
plumbing
shop.
There
are
2
typical
connections
as
shown
in
Figure
A,
B.
The
recommended
methods
of
drain
hose
connection
must
be
adhered
to
within
the
areas
of
Water
Board
Authority.
Several
other
options
are
commonly
used
outside
this
area
and
local
council
or
plumbers
should
be
able
to
advise
of
these.
The
"S"
trap
spigot
must
be
drilled
out
cleanly
and
free
of
obstruction
to
its
maximum
internal
diameter,
if
used
for
drainage.
To
prevent
siphoning,
one
of
the
following
instruction
methods
must
be
followed:
When
the
drainage
hose
is
connected
to
a
sink
"s"
trap
or
waste
disposal
unit,
the
hose
must
be
looped
up
to
the
underside
of
the
bench
top
and
secured.
When
the
drain
hose
is
connected
to
a
separate
stand
pipe,
it
is
essential
that
an
air
tight
connection
is
made.
Refer
to
Fig.B
Drain
Hose
Extension
Extend
drain
Hose
as
shown
below.
300 mm Min.
Drain
Hose
Water
Hose
Power
Cord
Radius
40mm
min
770 mm Min.
1000 mm Max.
770mm Min. / 1000 mm Max.
300 mm Min.
Air
Tight
Connection
Standpipe
40
mm
diametre
min.
Radius
40
mm
Min.
300 mm Min.
770 mm Min. / 1000 mm Max.
Sink
200
mm
Max.
Copper
pipe
Ø20mm
flared
at
drain
hose
and
other
end
if
required
Radius
40
mm
Min.
Drain
hose
extension
or
16-20mm
inside
Ørubber
hose
able
to
withstand
90˚C
hot
water
Fig.
A
Fig.
B
:
Drainage
connection
-
stand
pipe.