Note:
Thepropersubbasemustbeorderedtoobtainthecorrect
electricalreceptacle.(Figure60)
8. After wiring is complete, mount covers A and F to the
subbase with provided screws. (Figure 57)
9
. When installing optional accessories to the subbase, refer
to each installation instruction for that accessory.
Figure 55
Part/Location Identification
A
B
C
D
E
F
Left Front Cover
Right Front Cover
Front Cord Panel
Wall Sleeve Hole Location
Skirting Hole Location
Right Cover Assembly
Wall Sleeve
Cover
Wiring
Access
Subbase
Box Assy
Low Voltage
Compartment
2-13/16"
(71 mm)
11-13/1
6"
(3
00
mm
)
A
B
F
C
E
D
D
E
W
all Sleeve
(
Outdoor Side)
W
all Sleeve
I
nside Edge
B
ack of
Flange "A"
13 3/4"
2
3/4"
2 5/8"
13-7/8" (352 mm)
3-1/16"
(78 mm)
L
eft End View
Concentric
K
nockouts In Bottom
G
round
Screw Location
Receptacle Provided
Inside subbase
A
ccessory
T
op View
Concentric
Knockouts In Rear
Field Wiring
Line Voltage
Field Wiring
Line Voltage
NEMA 6-20R
Receptacle
230/208 VAC Field Schematic 265 VAC Field Schematic
NEMA 6-30R
Receptacle
Voltage Subbase ReceptacleUnit Plug
NEMA 7-30R
Receptacle
NEMA 7-20R
Receptacle
Front View
20-5/16" (515.5 mm)
2" (50 mm) Max.
Adjustment
4" (101 mm)
2-5/8" (67 mm)
2" (50 mm)
2
3/4"
1
6"
16"
1-3/8" (35 mm)
Figure 57 - Part/Location Identification
Figure 58 - Dimensions
Figure 59 - Wiring Diagram
Figure 60 - NEMA Plug Configurations